We may earn a commission if you buy through these links. It never changes a verdict. How this works

Will the Renogy 200W N-Type Solar Panel work with the Anker SOLIX C300X?

Yes. One Renogy 200W N-Type Solar Panel works with the Anker SOLIX C300X: about 25.2 V on a 20°F morning against the station's 28 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on XT60), about 100 W.

Verdict

Works

1 x 200W N-Type Solar Panel into the C300X (1 panel on XT60) stays inside 11 to 28 V, even at 20F.

1 x 200W N-Type Solar Panel1 panel on XT60
C300XXT60
Expected
100W
Voltage at 20F
25.2V
limit 28 V
Current
10.4A
cap not confirmed
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
  • The manual or page does not give a current limit for this input, so current was not checked.
  • Anker's page: use only 11 to 28V panels with an XT60 plug.
Cables to buy
  • Use an MC4 to XT60 solar cable.
Renogy 200W N-Type Solar Panel

200 W, open-circuit 23 V, short-circuit 11.1 A, working 19.2 V / 10.4 A. Brand page Panel details

Anker SOLIX C300X

Solar input XT60: 11 to 28 V, 100 W max. Brand page Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on XT60
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
XT6025.220.8100Works
2 panels in series on XT60
Open-circuit voltage 46V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
XT6050.410.40Don't connect

Quick answers

Will the Renogy 200W N-Type Solar Panel work with the Anker SOLIX C300X?

Yes. One Renogy 200W N-Type Solar Panel works with the Anker SOLIX C300X: about 25.2 V on a 20°F morning against the station's 28 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on XT60), about 100 W.

Can I connect two 200W N-Type Solar Panel panels to the C300X?

Yes, 2 panels in parallel on XT60. That gives about 100 W.

What cable do I need to connect the 200W N-Type Solar Panel to the C300X?

Use an MC4 to XT60 solar cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One 200W N-Type Solar Panel goes from 23 V on its label to about 25.2 V at 20°F and 26 V at 0°F. The C300X accepts up to 28 V on the XT60.

Where to buy

$180 at the Renogy store, Oct 28, 2026
Buy
Out of stock at the Anker SOLIX store
View at store

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the C300X

→Jackery SolarSaga 200 (JS-200E), about 100 W with two
→Jackery SolarSaga 200 (JS-200D), about 100 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 100 W with two
→BLUETTI PV200D, about 100 W with two
→EcoFlow 100W Rigid Solar Panel, about 100 W with two

All 33 panels checked against the C300X

Rules we applied
  • Anker SOLIX C300X: solar input 11 to 28 V on the Solar in (XT60). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 23 V becomes 25.2 V.
  • The current limit for this input is not confirmed yet.
  • Max 100 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
From the brand's pageC300X spec page, solar input
Checked Oct 28, 2026