Will the Anker SOLIX PS200 Bifacial work with the Anker SOLIX C300X?

No. Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it. Two panels: don't connect (2 panels in parallel on XT60), about 0 W.

Verdict

Don't connect

Do not plug this in. Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it.

1 x PS200 Bifacial1 panel on XT60
C300XXT60
Expected
0W
Voltage at 20F
63.1V
limit 28 V
Current
4.2A
cap 8.2 A
  • Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
  • Anker's page: use only 11 to 28V panels with an XT60 plug.
Cables to buyNone. Do not connect this combination. Pick a panel with lower open-circuit voltage, or fewer in series.
Anker SOLIX PS200 Bifacial

200 W, open-circuit 57.6 V, short-circuit 4.4 A, working 48 V / 4.2 A. Unconfirmed Panel details

Anker SOLIX C300X

Solar input XT60: 11 to 28 V, 100 W max. Manual Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on XT60
Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
XT6063.18.30Don't connect
2 panels in series on XT60
Open-circuit voltage 115.2V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
XT60126.14.20Don't connect

Quick answers

Will the Anker SOLIX PS200 Bifacial work with the Anker SOLIX C300X?

No. Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it. Two panels: don't connect (2 panels in parallel on XT60), about 0 W.

Can I connect two PS200 Bifacial panels to the C300X?

No: Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it.

Is it safe on a cold morning?

Panel voltage rises in the cold. One PS200 Bifacial goes from 57.6 V on its label to about 63.1 V at 20°F and 65 V at 0°F. The C300X accepts up to 28 V on the XT60.

Where to buy

$500 at the Anker SOLIX store, Oct 28, 2026
BuyAmazon
Out of stock at the Anker SOLIX store
View at store

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the C300X

→Jackery SolarSaga 200 (JS-200E), about 100 W with two
→Jackery SolarSaga 200 (JS-200D), about 100 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 100 W with two
→BLUETTI PV200D, about 100 W with two
→EcoFlow 100W Rigid Solar Panel, about 100 W with two

All 33 panels checked against the C300X

Rules we applied
  • Anker SOLIX C300X: solar input 11 to 28 V on the Solar in (XT60). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 57.6 V becomes 63.1 V.
  • Current over the 8.2 A cap is safe: the station takes 8.2 A and you get fewer watts. We count only the capped watts.
  • Max 100 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
  • Some numbers for Anker SOLIX PS200 Bifacial come from a shop listing we have not confirmed in the manual yet.
Sources
Shop listing, not yet confirmedPS200 Bifacial label values
Checked Oct 28, 2026