Will the Anker SOLIX PS400 Bifacial work with the Anker SOLIX C200X?
No. Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it. Two panels: don't connect (2 panels in parallel on XT60), about 0 W.
Don't connect
Do not plug this in. Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
- Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
- The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
- The manual or page does not give a current limit for this input, so current was not checked.
- Anker's page: use only 11 to 28V panels with an XT60 plug.
- 57.6 V open circuit: above the 55-60 V limit of many smaller stations even as a single panel on a cold morning.
400 W, open-circuit 57.6 V, short-circuit 8.8 A, working 48 V / 8.3 A. Unconfirmed Panel details
Anker SOLIX C200XSolar input XT60: 11 to 28 V, 100 W max. Brand page Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 2 panels in parallel on XT60 Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it. | XT60 | 63.1 | 16.7 | 0 | Don't connect |
| 2 panels in series on XT60 Open-circuit voltage 115.2V is above the station's 28V limit. Going over a station's input voltage limit can damage it. | XT60 | 126.1 | 8.3 | 0 | Don't connect |
Quick answers
Will the Anker SOLIX PS400 Bifacial work with the Anker SOLIX C200X?
No. Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it. Two panels: don't connect (2 panels in parallel on XT60), about 0 W.
Can I connect two PS400 Bifacial panels to the C200X?
No: Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
Is it safe on a cold morning?
Panel voltage rises in the cold. One PS400 Bifacial goes from 57.6 V on its label to about 63.1 V at 20°F and 65 V at 0°F. The C200X accepts up to 28 V on the XT60.
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the C200X
- Anker SOLIX C200X: solar input 11 to 28 V on the Solar in (XT60). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
- Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 57.6 V becomes 63.1 V.
- The current limit for this input is not confirmed yet.
- Max 100 W on this input.
- Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
- Some numbers for Anker SOLIX PS400 Bifacial come from a shop listing we have not confirmed in the manual yet.