Will the Rich Solar MEGA 50 work with the Anker SOLIX C2000 Gen 2?
Yes. One Rich Solar MEGA 50 works with the Anker SOLIX C2000 Gen 2: about 22.8 V on a 20°F morning against the station's 60 V limit, and about 50 W in full sun. Two panels: works (2 panels in parallel on Solar input), about 100 W.
Works
1 x MEGA 50 into the C2000 Gen 2 (1 panel on Solar input) stays inside 11 to 60 V and under 17 A, even at 20F.
- The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
- Anker does not say whether its voltage limit is open-circuit or working voltage, so the checker uses the stricter reading.
- Use the solar charging cable that came with the station (MC4 on the panel side).
50 W, open-circuit 20.8 V, short-circuit 3.1 A, working 17.6 V / 2.8 A. Brand page Panel details
Anker SOLIX C2000 Gen 2Solar input Solar input: 11 to 60 V, 800 W max. Brand page Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 2 panels in parallel on Solar input The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | Solar input | 22.8 | 5.7 | 100 | Works |
| 2 panels in series on Solar input The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | Solar input | 45.6 | 2.8 | 100 | Works |
Quick answers
Will the Rich Solar MEGA 50 work with the Anker SOLIX C2000 Gen 2?
Yes. One Rich Solar MEGA 50 works with the Anker SOLIX C2000 Gen 2: about 22.8 V on a 20°F morning against the station's 60 V limit, and about 50 W in full sun. Two panels: works (2 panels in parallel on Solar input), about 100 W.
Can I connect two MEGA 50 panels to the C2000 Gen 2?
Yes, 2 panels in parallel on Solar input. That gives about 100 W.
What cable do I need to connect the MEGA 50 to the C2000 Gen 2?
Use the solar charging cable that came with the station (MC4 on the panel side).
Is it safe on a cold morning?
Panel voltage rises in the cold. One MEGA 50 goes from 20.8 V on its label to about 22.8 V at 20°F and 23.5 V at 0°F. The C2000 Gen 2 accepts up to 60 V on the Solar input.
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the C2000 Gen 2
- Anker SOLIX C2000 Gen 2: solar input 11 to 60 V on the Solar in (Solar input). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
- Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 20.8 V becomes 22.8 V.
- Current over the 17 A cap is safe: the station takes 17 A and you get fewer watts. We count only the capped watts.
- Max 800 W on this input.
- Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.