We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup

Will the Rich Solar MEGA 200 work with the Anker SOLIX C2000 Gen 2?

Yes. One Rich Solar MEGA 200 works with the Anker SOLIX C2000 Gen 2: about 23.9 V on a 20°F morning against the station's 60 V limit, and about 200 W in full sun. Two panels: works (2 panels in series on Solar input), about 400 W.

Verdict

Works

1 x MEGA 200 into the C2000 Gen 2 (1 panel on Solar input) stays inside 11 to 60 V and under 17 A, even at 20F.

1 x MEGA 2001 panel on Solar input
C2000 Gen 2Solar input
Expected
200W
Voltage at 20F
23.9V
limit 60 V
Current
10.9A
cap 17 A
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
  • Anker does not say whether its voltage limit is open-circuit or working voltage, so the checker uses the stricter reading.
Cables to buy
  • Use the solar charging cable that came with the station (MC4 on the panel side).
Rich Solar MEGA 200

200 W, open-circuit 21.8 V, short-circuit 11.6 A, working 18.4 V / 10.9 A. Brand page Panel details

Anker SOLIX C2000 Gen 2

Solar input Solar input: 11 to 60 V, 800 W max. Brand page Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in series on Solar input
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Solar input47.710.9400Works
2 panels in parallel on Solar input
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Solar input23.921.8313Works

Quick answers

Will the Rich Solar MEGA 200 work with the Anker SOLIX C2000 Gen 2?

Yes. One Rich Solar MEGA 200 works with the Anker SOLIX C2000 Gen 2: about 23.9 V on a 20°F morning against the station's 60 V limit, and about 200 W in full sun. Two panels: works (2 panels in series on Solar input), about 400 W.

Can I connect two MEGA 200 panels to the C2000 Gen 2?

Yes, 2 panels in series on Solar input. That gives about 400 W.

What cable do I need to connect the MEGA 200 to the C2000 Gen 2?

Use the solar charging cable that came with the station (MC4 on the panel side).

Is it safe on a cold morning?

Panel voltage rises in the cold. One MEGA 200 goes from 21.8 V on its label to about 23.9 V at 20°F and 24.6 V at 0°F. The C2000 Gen 2 accepts up to 60 V on the Solar input.

Where to buy

$240 at the Rich Solar store, Oct 28, 2026
BuyAmazon
$1,200 at the Anker SOLIX store, Oct 28, 2026
Buy

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the C2000 Gen 2

→EcoFlow 400W Portable Solar Panel, about 697 W with two
→Renogy 250W N-Type Bifacial Solar Panel, about 500 W with two
→BLUETTI PV350D, about 469 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 438 W with two
→Jackery SolarSaga 200 (JS-200E), about 400 W with two

All 33 panels checked against the C2000 Gen 2

Rules we applied
  • Anker SOLIX C2000 Gen 2: solar input 11 to 60 V on the Solar in (Solar input). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 21.8 V becomes 23.9 V.
  • Current over the 17 A cap is safe: the station takes 17 A and you get fewer watts. We count only the capped watts.
  • Max 800 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
From the brand's pageMEGA 200 label values
Checked Oct 28, 2026