{"name":"RidgeWatt portable power station and solar panel data","url":"https://ridgewatt.com/data/","license":"CC BY 4.0","attribution":"RidgeWatt (ridgewatt.com)","prices_checked":"Oct 28, 2026","stations":[{"id":"ecoflow-river-3-plus","brand":"EcoFlow","model":"RIVER 3 Plus","model_no":"EF-RV-H02-1","capacity_wh":286,"ac_output_w":600,"surge_w":1200,"chemistry":"LiFePO4","weight_lb":10.4,"solar_input_total_w":220,"solar_inputs":"XT60i 11-55V 13A voc","source_type":"manual","source_url":"https://manuals.ecoflow.com/product/river-3-plus","price_usd":299,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/ecoflow-river-3-plus-portable-power-station-flash-sale","page":"https://ridgewatt.com/stations/ecoflow-river-3-plus/"},{"id":"ecoflow-delta-3-plus","brand":"EcoFlow","model":"DELTA 3 Plus","model_no":"EF-DL-H10-4","capacity_wh":1024,"ac_output_w":1800,"surge_w":3600,"chemistry":"LiFePO4","weight_lb":27.6,"solar_input_total_w":1000,"solar_inputs":"XT60i 11-60V 15A voc | XT60i 11-60V 15A voc","source_type":"manual","source_url":"https://manuals.ecoflow.com/us/product/delta-3-plus","price_usd":719,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/delta-3-plus-portable-power-station","page":"https://ridgewatt.com/stations/ecoflow-delta-3-plus/"},{"id":"ecoflow-delta-pro-3","brand":"EcoFlow","model":"DELTA Pro 3","model_no":"EFD521","capacity_wh":4096,"ac_output_w":4000,"surge_w":8000,"chemistry":"LiFePO4","weight_lb":113.5,"solar_input_total_w":2600,"solar_inputs":"XT60 (High-PV) 30-150V 15A voc | XT60i (Low-PV) 11-60V 20A voc","source_type":"manual","source_url":"https://manuals.ecoflow.com/us/product/delta-pro-3","price_usd":2799,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/delta-pro-3-portable-power-station","page":"https://ridgewatt.com/stations/ecoflow-delta-pro-3/"},{"id":"jackery-explorer-300-plus","brand":"Jackery","model":"Explorer 300 Plus","model_no":"JE-300B","capacity_wh":288,"ac_output_w":300,"surge_w":600,"chemistry":null,"weight_lb":8.3,"solar_input_total_w":100,"solar_inputs":"USB-C 12-27V 5A unspecified","source_type":"manual","source_url":"https://static.rapidonline.com/pdf/09-5203m_v1.pdf","price_usd":null,"price_checked":"Oct 28, 2026","store_url":null,"page":"https://ridgewatt.com/stations/jackery-explorer-300-plus/"},{"id":"jackery-explorer-1000-v2","brand":"Jackery","model":"Explorer 1000 v2","model_no":"JE-1000D","capacity_wh":1070,"ac_output_w":1500,"surge_w":3000,"chemistry":"LiFePO4","weight_lb":23.8,"solar_input_total_w":400,"solar_inputs":"DC8020 12-60V 10.5A working | DC8020 12-60V 10.5A working","source_type":"manual","source_url":"https://www.mrsolar.com/content/pdf/jackery/jackery-1000-v2.pdf","price_usd":519,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/jackery-explorer-1000-v2","page":"https://ridgewatt.com/stations/jackery-explorer-1000-v2/"},{"id":"jackery-explorer-2000-plus","brand":"Jackery","model":"Explorer 2000 Plus","model_no":"JE-2000C","capacity_wh":2042.8,"ac_output_w":3000,"surge_w":6000,"chemistry":"LiFePO4","weight_lb":61.5,"solar_input_total_w":1400,"solar_inputs":"DC8020 11-60V 12A working | DC8020 11-60V 12A working","source_type":"manual","source_url":"https://images.thdstatic.com/catalog/pdfImages/29/294b06bd-196e-4a98-882e-8b6dfd01b283.pdf","price_usd":2899,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/explorer-2000-plus-portable-power-station","page":"https://ridgewatt.com/stations/jackery-explorer-2000-plus/"},{"id":"bluetti-ac70","brand":"BLUETTI","model":"AC70","model_no":null,"capacity_wh":768,"ac_output_w":1000,"surge_w":1500,"chemistry":"LiFePO4","weight_lb":22.5,"solar_input_total_w":500,"solar_inputs":"XT60 (XT60PM-M) 12-58V 10A voc","source_type":"manual","source_url":"https://s4.bluettipower.com/bluetti_lgf/support/2025/08/cf1dccbc-dc4d-429c-9e53-82ae141490de.pdf","price_usd":359,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/ac70","page":"https://ridgewatt.com/stations/bluetti-ac70/"},{"id":"bluetti-ac180","brand":"BLUETTI","model":"AC180","model_no":null,"capacity_wh":1152,"ac_output_w":1800,"surge_w":2700,"chemistry":"LiFePO4","weight_lb":35.3,"solar_input_total_w":500,"solar_inputs":"DC7909 12-60V 10A voc","source_type":"manual","source_url":"https://cdn.shopify.com/s/files/1/0536/3390/8911/files/AC180_User_Manual_6812221c-ec19-42ce-8aba-ef1f72152d98.pdf","price_usd":499,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/ac180","page":"https://ridgewatt.com/stations/bluetti-ac180/"},{"id":"bluetti-ac200l","brand":"BLUETTI","model":"AC200L","model_no":null,"capacity_wh":2048,"ac_output_w":2400,"surge_w":3600,"chemistry":"LiFePO4","weight_lb":62.4,"solar_input_total_w":1200,"solar_inputs":"DC input (via DC input cable + solar charging cable) 12-145V 15A voc","source_type":"manual","source_url":"https://s4.bluettipower.com/bluetti_lgf/support/2025/05/cca63f10-4c44-4b89-9e33-d235f2c19f93.pdf","price_usd":899,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/ac200l-portable-power-station","page":"https://ridgewatt.com/stations/bluetti-ac200l/"},{"id":"anker-solix-c1000-gen2","brand":"Anker SOLIX","model":"C1000 Gen 2","model_no":null,"capacity_wh":1024,"ac_output_w":2000,"surge_w":3000,"chemistry":null,"weight_lb":24.9,"solar_input_total_w":600,"solar_inputs":"XT60i 11-60V 14.5A unspecified","source_type":"official product page","source_url":"https://www.ankersolix.com/products/c1000-gen2","price_usd":699.99,"price_checked":"Oct 28, 2026","store_url":"https://www.ankersolix.com/products/c1000-gen2","page":"https://ridgewatt.com/stations/anker-solix-c1000-gen2/"},{"id":"ecoflow-river-2","brand":"EcoFlow","model":"RIVER 2","model_no":null,"capacity_wh":243,"ac_output_w":300,"surge_w":600,"chemistry":"LiFePO4","weight_lb":7.7,"solar_input_total_w":110,"solar_inputs":"Solar input 11-30V 8A voc","source_type":"official product page","source_url":"https://us.ecoflow.com/products/river-2-240-portable-power-station","price_usd":219,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/river-2-240-portable-power-station","page":"https://ridgewatt.com/stations/ecoflow-river-2/"},{"id":"ecoflow-river-2-max","brand":"EcoFlow","model":"RIVER 2 Max","model_no":null,"capacity_wh":512,"ac_output_w":500,"surge_w":1000,"chemistry":"LiFePO4","weight_lb":13.4,"solar_input_total_w":220,"solar_inputs":"Solar input 11-50V 13A voc","source_type":"official product page","source_url":"https://us.ecoflow.com/products/river-2-max-portable-power-station","price_usd":289,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/river-2-max-portable-power-station","page":"https://ridgewatt.com/stations/ecoflow-river-2-max/"},{"id":"ecoflow-river-2-max-500","brand":"EcoFlow","model":"RIVER 2 Max 500","model_no":null,"capacity_wh":499,"ac_output_w":500,"surge_w":1000,"chemistry":"LiFePO4","weight_lb":13.2,"solar_input_total_w":220,"solar_inputs":"Solar input 11-50V 13A voc","source_type":"official product page","source_url":"https://us.ecoflow.com/products/river-2-max-500-portable-power-station","price_usd":329,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/river-2-max-500-portable-power-station","page":"https://ridgewatt.com/stations/ecoflow-river-2-max-500/"},{"id":"ecoflow-river-2-pro","brand":"EcoFlow","model":"RIVER 2 Pro","model_no":null,"capacity_wh":768,"ac_output_w":800,"surge_w":1600,"chemistry":"LiFePO4","weight_lb":18.2,"solar_input_total_w":220,"solar_inputs":"Solar input 11-50V 13A voc","source_type":"official product page","source_url":"https://us.ecoflow.com/products/river-2-pro-portable-power-station","price_usd":389,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/river-2-pro-portable-power-station","page":"https://ridgewatt.com/stations/ecoflow-river-2-pro/"},{"id":"ecoflow-trail-200-dc","brand":"EcoFlow","model":"TRAIL 200 DC","model_no":null,"capacity_wh":192,"ac_output_w":null,"surge_w":null,"chemistry":"LiFePO4","weight_lb":4,"solar_input_total_w":null,"solar_inputs":"","source_type":"official product page","source_url":"https://us.ecoflow.com/products/trail-series","price_usd":119,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/trail-series","page":"https://ridgewatt.com/stations/ecoflow-trail-200-dc/"},{"id":"ecoflow-trail-300-dc","brand":"EcoFlow","model":"TRAIL 300 DC","model_no":null,"capacity_wh":288,"ac_output_w":null,"surge_w":null,"chemistry":"LiFePO4","weight_lb":5.7,"solar_input_total_w":110,"solar_inputs":"Solar/Car input (XT60) 10-30V 10A voc","source_type":"manual","source_url":"https://www.qvc.com/footers/el/pdf/E329628_User_Manual.pdf","price_usd":159,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/trail-series","page":"https://ridgewatt.com/stations/ecoflow-trail-300-dc/"},{"id":"ecoflow-trail-plus-300-dc","brand":"EcoFlow","model":"TRAIL Plus 300 DC","model_no":null,"capacity_wh":288,"ac_output_w":null,"surge_w":null,"chemistry":"NCM","weight_lb":5,"solar_input_total_w":110,"solar_inputs":"Solar/Car input ?-?V ?A voc","source_type":"official product page","source_url":"https://us.ecoflow.com/products/trail-series","price_usd":199,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/trail-series","page":"https://ridgewatt.com/stations/ecoflow-trail-plus-300-dc/"},{"id":"ecoflow-delta-3-classic","brand":"EcoFlow","model":"DELTA 3 Classic","model_no":null,"capacity_wh":1024,"ac_output_w":1800,"surge_w":3600,"chemistry":"LiFePO4","weight_lb":26.6,"solar_input_total_w":500,"solar_inputs":"Solar/Car input (XT60i) 11-60V 15A voc","source_type":"manual","source_url":"https://manuals.ecoflow.com/us/product/delta-3-classic?lang=en_US","price_usd":499,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/delta-3-classic-portable-power-station","page":"https://ridgewatt.com/stations/ecoflow-delta-3-classic/"},{"id":"ecoflow-delta-3","brand":"EcoFlow","model":"DELTA 3","model_no":null,"capacity_wh":1024,"ac_output_w":1800,"surge_w":3600,"chemistry":"LiFePO4","weight_lb":27.6,"solar_input_total_w":500,"solar_inputs":"Solar/Car input (XT60i) 11-60V 15A voc","source_type":"manual","source_url":"https://manuals.ecoflow.com/us/product/delta-3?lang=en_US","price_usd":629,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/delta-3-portable-power-station","page":"https://ridgewatt.com/stations/ecoflow-delta-3/"},{"id":"ecoflow-delta-3-max","brand":"EcoFlow","model":"DELTA 3 Max","model_no":null,"capacity_wh":2048,"ac_output_w":2400,"surge_w":4800,"chemistry":"LiFePO4","weight_lb":44.8,"solar_input_total_w":500,"solar_inputs":"Solar/Car input (XT60i) 11-60V 13A voc","source_type":"manual","source_url":"https://manuals.ecoflow.com/us/product/delta-3-max?lang=en_US","price_usd":899,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/ecoflow-delta-3-max-portable-power-station-2048wh","page":"https://ridgewatt.com/stations/ecoflow-delta-3-max/"},{"id":"ecoflow-delta-3-max-plus","brand":"EcoFlow","model":"DELTA 3 Max Plus","model_no":null,"capacity_wh":2048,"ac_output_w":3000,"surge_w":6000,"chemistry":"LiFePO4","weight_lb":48.7,"solar_input_total_w":1000,"solar_inputs":"Solar/Car input 1 (XT60i) 11-60V 18A voc | Solar/Car input 2 (XT60i) 11-60V 18A voc","source_type":"manual","source_url":"https://manuals.ecoflow.com/us/product/delta-3-max-plus?lang=en_US","price_usd":1199,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/ecoflow-delta-3-max-plus-portable-power-station-2048wh","page":"https://ridgewatt.com/stations/ecoflow-delta-3-max-plus/"},{"id":"ecoflow-delta-3-ultra","brand":"EcoFlow","model":"DELTA 3 Ultra","model_no":null,"capacity_wh":3072,"ac_output_w":3600,"surge_w":7200,"chemistry":"LiFePO4","weight_lb":72.1,"solar_input_total_w":800,"solar_inputs":"Solar input (XT60i) 11-60V 18A voc","source_type":"manual","source_url":"https://manuals.ecoflow.com/us/product/delta-3-ultra?lang=en_US","price_usd":1349,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/ecoflow-delta-3-ultra-portable-power-station-3072wh","page":"https://ridgewatt.com/stations/ecoflow-delta-3-ultra/"},{"id":"ecoflow-delta-3-ultra-plus","brand":"EcoFlow","model":"DELTA 3 Ultra Plus","model_no":null,"capacity_wh":3072,"ac_output_w":3600,"surge_w":7200,"chemistry":"LiFePO4","weight_lb":74.3,"solar_input_total_w":1600,"solar_inputs":"Solar input 1 (XT60i) 11-60V 18A voc | Solar input 2 (XT60i) 11-60V 18A voc","source_type":"manual","source_url":"https://manuals.ecoflow.com/us/product/delta-3-ultra-plus?lang=en_US","price_usd":1599,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/ecoflow-delta-3-ultra-plus-portable-power-station-3072wh","page":"https://ridgewatt.com/stations/ecoflow-delta-3-ultra-plus/"},{"id":"ecoflow-delta-2-max","brand":"EcoFlow","model":"DELTA 2 Max","model_no":null,"capacity_wh":2048,"ac_output_w":2400,"surge_w":4800,"chemistry":"LiFePO4","weight_lb":50,"solar_input_total_w":1000,"solar_inputs":"Solar input 11-60V 15A voc | Solar input 11-60V 15A voc","source_type":"official product page","source_url":"https://us.ecoflow.com/products/delta-2-max-portable-power-station","price_usd":1049,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/delta-2-max-portable-power-station","page":"https://ridgewatt.com/stations/ecoflow-delta-2-max/"},{"id":"ecoflow-delta-pro","brand":"EcoFlow","model":"DELTA Pro","model_no":null,"capacity_wh":3600,"ac_output_w":3600,"surge_w":7200,"chemistry":"LiFePO4","weight_lb":99,"solar_input_total_w":1600,"solar_inputs":"Solar input 11-150V 15A voc","source_type":"official product page","source_url":"https://us.ecoflow.com/products/delta-pro-portable-power-station","price_usd":1899,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/delta-pro-portable-power-station","page":"https://ridgewatt.com/stations/ecoflow-delta-pro/"},{"id":"ecoflow-delta-pro-ultra","brand":"EcoFlow","model":"DELTA Pro Ultra","model_no":null,"capacity_wh":6144,"ac_output_w":7200,"surge_w":10800,"chemistry":"LiFePO4","weight_lb":null,"solar_input_total_w":5600,"solar_inputs":"High-PV 80-450V 15A voc | Low-PV 30-150V 15A voc","source_type":"official product page","source_url":"https://us.ecoflow.com/products/delta-pro-ultra","price_usd":4199,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/delta-pro-ultra","page":"https://ridgewatt.com/stations/ecoflow-delta-pro-ultra/"},{"id":"ecoflow-delta-pro-ultra-x","brand":"EcoFlow","model":"DELTA Pro Ultra X","model_no":null,"capacity_wh":12288,"ac_output_w":12000,"surge_w":null,"chemistry":"LiFePO4","weight_lb":null,"solar_input_total_w":10000,"solar_inputs":"High-PV 80-500V 15A voc | High-PV 80-500V 15A voc","source_type":"official product page","source_url":"https://us.ecoflow.com/products/delta-pro-ultra-x","price_usd":7999,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/delta-pro-ultra-x","page":"https://ridgewatt.com/stations/ecoflow-delta-pro-ultra-x/"},{"id":"ecoflow-delta-mini","brand":"EcoFlow","model":"DELTA mini","model_no":null,"capacity_wh":882,"ac_output_w":1400,"surge_w":2100,"chemistry":"NCM","weight_lb":23.6,"solar_input_total_w":300,"solar_inputs":"Solar input 11-75V 10A voc","source_type":"official product page","source_url":"https://us.ecoflow.com/products/delta-mini-portable-power-station","price_usd":549,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/delta-mini-portable-power-station","page":"https://ridgewatt.com/stations/ecoflow-delta-mini/"},{"id":"ecoflow-delta-1300","brand":"EcoFlow","model":"DELTA 1300 (1260Wh)","model_no":null,"capacity_wh":1260,"ac_output_w":1800,"surge_w":3300,"chemistry":"Li-ion","weight_lb":30.9,"solar_input_total_w":400,"solar_inputs":"Solar input 10-65V 10A voc","source_type":"official product page","source_url":"https://us.ecoflow.com/products/delta-portable-power-station","price_usd":749,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/delta-portable-power-station","page":"https://ridgewatt.com/stations/ecoflow-delta-1300/"},{"id":"ecoflow-delta-1000","brand":"EcoFlow","model":"DELTA 1000","model_no":null,"capacity_wh":1008,"ac_output_w":1600,"surge_w":3100,"chemistry":"NCM","weight_lb":30.9,"solar_input_total_w":400,"solar_inputs":"Solar input 10-65V 10A voc","source_type":"official product page","source_url":"https://us.ecoflow.com/products/delta-portable-power-station","price_usd":699,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/delta-portable-power-station","page":"https://ridgewatt.com/stations/ecoflow-delta-1000/"},{"id":"ecoflow-river-max","brand":"EcoFlow","model":"RIVER Max","model_no":null,"capacity_wh":576,"ac_output_w":600,"surge_w":1200,"chemistry":"Li-ion","weight_lb":17,"solar_input_total_w":200,"solar_inputs":"Solar input 10-25V 12A voc","source_type":"official product page","source_url":"https://us.ecoflow.com/products/river-max-portable-power-station","price_usd":449,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/river-max-portable-power-station","page":"https://ridgewatt.com/stations/ecoflow-river-max/"},{"id":"ecoflow-river-max-plus","brand":"EcoFlow","model":"RIVER Max Plus","model_no":null,"capacity_wh":720,"ac_output_w":600,"surge_w":1200,"chemistry":"NCM","weight_lb":17.6,"solar_input_total_w":200,"solar_inputs":"Solar input 10-25V 12A voc","source_type":"official product page","source_url":"https://us.ecoflow.com/products/river-max-plus-portable-power-station","price_usd":499,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/river-max-plus-portable-power-station","page":"https://ridgewatt.com/stations/ecoflow-river-max-plus/"},{"id":"ecoflow-river-mini","brand":"EcoFlow","model":"RIVER mini","model_no":null,"capacity_wh":210,"ac_output_w":300,"surge_w":600,"chemistry":"NCM","weight_lb":6.3,"solar_input_total_w":100,"solar_inputs":"DC input 11-39V 8A voc","source_type":"official product page","source_url":"https://us.ecoflow.com/products/river-mini-portable-power-station","price_usd":399,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/river-mini-portable-power-station","page":"https://ridgewatt.com/stations/ecoflow-river-mini/"},{"id":"ecoflow-river-plus","brand":"EcoFlow","model":"RIVER Plus","model_no":null,"capacity_wh":360,"ac_output_w":600,"surge_w":1200,"chemistry":"NCM","weight_lb":11.9,"solar_input_total_w":200,"solar_inputs":"Solar input 10-25V 12A voc","source_type":"official product page","source_url":"https://us.ecoflow.com/products/river-plus-portable-power-station","price_usd":249,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/river-plus-portable-power-station","page":"https://ridgewatt.com/stations/ecoflow-river-plus/"},{"id":"ecoflow-river-pro","brand":"EcoFlow","model":"RIVER Pro","model_no":null,"capacity_wh":720,"ac_output_w":600,"surge_w":1200,"chemistry":null,"weight_lb":16.8,"solar_input_total_w":null,"solar_inputs":"Solar input ?-?V ?A voc","source_type":"official product page","source_url":"https://us.ecoflow.com/products/river-pro-portable-power-station-costco-sale","price_usd":549,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/river-pro-portable-power-station-costco-sale","page":"https://ridgewatt.com/stations/ecoflow-river-pro/"},{"id":"ecoflow-river","brand":"EcoFlow","model":"RIVER","model_no":null,"capacity_wh":288,"ac_output_w":600,"surge_w":1200,"chemistry":"Li-ion","weight_lb":11,"solar_input_total_w":200,"solar_inputs":"Solar input 10-25V 12A voc","source_type":"official product page","source_url":"https://us.ecoflow.com/products/river-portable-power-station","price_usd":349,"price_checked":"Oct 28, 2026","store_url":"https://us.ecoflow.com/products/river-portable-power-station","page":"https://ridgewatt.com/stations/ecoflow-river/"},{"id":"bluetti-eb3a","brand":"BLUETTI","model":"EB3A","model_no":null,"capacity_wh":268.8,"ac_output_w":600,"surge_w":1200,"chemistry":"LiFePO4","weight_lb":10.1,"solar_input_total_w":200,"solar_inputs":"Solar input 12-28V 8.5A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/bluetti-eb3a-portable-power-station","price_usd":219,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/bluetti-eb3a-portable-power-station","page":"https://ridgewatt.com/stations/bluetti-eb3a/"},{"id":"bluetti-ac2a","brand":"BLUETTI","model":"AC2A","model_no":null,"capacity_wh":204.8,"ac_output_w":300,"surge_w":600,"chemistry":"LiFePO4","weight_lb":7.9,"solar_input_total_w":200,"solar_inputs":"Solar input 12-28V 8.2A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/ac2a","price_usd":149,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/ac2a","page":"https://ridgewatt.com/stations/bluetti-ac2a/"},{"id":"bluetti-ac60","brand":"BLUETTI","model":"Pioneer 50 (AC60)","model_no":null,"capacity_wh":403,"ac_output_w":600,"surge_w":1200,"chemistry":"LiFePO4","weight_lb":20.1,"solar_input_total_w":200,"solar_inputs":"Solar input 12-28V 8A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/ac60","price_usd":599,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/ac60","page":"https://ridgewatt.com/stations/bluetti-ac60/"},{"id":"bluetti-ac180t","brand":"BLUETTI","model":"Pioneer MD (AC180T)","model_no":null,"capacity_wh":1433.6,"ac_output_w":1800,"surge_w":3600,"chemistry":"LiFePO4","weight_lb":58.4,"solar_input_total_w":500,"solar_inputs":"Solar input (XT60) 12-60V 10A voc","source_type":"manual","source_url":"https://s4.bluettipower.com/bluetti_lgf/support/2025/05/f8d5a435-53d8-43f8-b96f-956531e891b4.pdf","price_usd":799,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/ac180t","page":"https://ridgewatt.com/stations/bluetti-ac180t/"},{"id":"bluetti-ac240","brand":"BLUETTI","model":"Pioneer 150 (AC240)","model_no":null,"capacity_wh":1536,"ac_output_w":2400,"surge_w":null,"chemistry":"LiFePO4","weight_lb":72,"solar_input_total_w":1200,"solar_inputs":"Solar input 11-60V 21A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/ac240","price_usd":999,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/ac240","page":"https://ridgewatt.com/stations/bluetti-ac240/"},{"id":"bluetti-apex-300","brand":"BLUETTI","model":"Apex 300","model_no":null,"capacity_wh":2764.8,"ac_output_w":3840,"surge_w":null,"chemistry":"LiFePO4","weight_lb":83.8,"solar_input_total_w":2400,"solar_inputs":"Solar input 12-60V 20A voc | Solar input 12-60V 20A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/apex-300-home-battery-backup","price_usd":1599,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/apex-300-home-battery-backup","page":"https://ridgewatt.com/stations/bluetti-apex-300/"},{"id":"bluetti-ac180p","brand":"BLUETTI","model":"AC180P","model_no":null,"capacity_wh":1440,"ac_output_w":1800,"surge_w":2700,"chemistry":"LiFePO4","weight_lb":35.3,"solar_input_total_w":500,"solar_inputs":"Solar input 12-60V 10A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/ac180p","price_usd":649,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/ac180p","page":"https://ridgewatt.com/stations/bluetti-ac180p/"},{"id":"bluetti-ac200max","brand":"BLUETTI","model":"AC200MAX","model_no":null,"capacity_wh":2048,"ac_output_w":2200,"surge_w":4800,"chemistry":"LiFePO4","weight_lb":61.9,"solar_input_total_w":900,"solar_inputs":"Solar input 10-145V 15A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/ac200max-power-station","price_usd":1199,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/ac200max-power-station","page":"https://ridgewatt.com/stations/bluetti-ac200max/"},{"id":"bluetti-ac200p-l","brand":"BLUETTI","model":"AC200P L","model_no":null,"capacity_wh":2304,"ac_output_w":2400,"surge_w":3600,"chemistry":"LiFePO4","weight_lb":63.5,"solar_input_total_w":1200,"solar_inputs":"Solar input 12-145V 15A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/ac200p-l","price_usd":1399,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/ac200p-l","page":"https://ridgewatt.com/stations/bluetti-ac200p-l/"},{"id":"bluetti-ac200p","brand":"BLUETTI","model":"AC200P","model_no":null,"capacity_wh":2000,"ac_output_w":2000,"surge_w":4800,"chemistry":"LiFePO4","weight_lb":60.6,"solar_input_total_w":700,"solar_inputs":"Solar input 35-150V 12A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/bluetti-ac200p-2000wh-2000w-portable-power-station","price_usd":1099,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/bluetti-ac200p-2000wh-2000w-portable-power-station","page":"https://ridgewatt.com/stations/bluetti-ac200p/"},{"id":"bluetti-ac50b","brand":"BLUETTI","model":"AC50B","model_no":null,"capacity_wh":448,"ac_output_w":700,"surge_w":null,"chemistry":"LiFePO4","weight_lb":14.8,"solar_input_total_w":200,"solar_inputs":"Solar input 12-28V 8.5A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/ac50b","price_usd":399,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/ac50b","page":"https://ridgewatt.com/stations/bluetti-ac50b/"},{"id":"bluetti-ac50p","brand":"BLUETTI","model":"AC50P","model_no":null,"capacity_wh":504,"ac_output_w":700,"surge_w":null,"chemistry":"LiFePO4","weight_lb":15.1,"solar_input_total_w":200,"solar_inputs":"Solar input 12-28V 8.5A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/bluetti-ac50p-portable-power-station","price_usd":339,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/bluetti-ac50p-portable-power-station","page":"https://ridgewatt.com/stations/bluetti-ac50p/"},{"id":"bluetti-ac70p","brand":"BLUETTI","model":"AC70P","model_no":null,"capacity_wh":864,"ac_output_w":1000,"surge_w":2000,"chemistry":"LiFePO4","weight_lb":22.5,"solar_input_total_w":500,"solar_inputs":"Solar input 12-58V 10A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/bluetti-ac70p","price_usd":469,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/bluetti-ac70p","page":"https://ridgewatt.com/stations/bluetti-ac70p/"},{"id":"bluetti-eb70s","brand":"BLUETTI","model":"EB70S","model_no":null,"capacity_wh":716,"ac_output_w":800,"surge_w":1400,"chemistry":"LiFePO4","weight_lb":21.4,"solar_input_total_w":200,"solar_inputs":"Solar input 12-28V 8A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/eb70s-716wh-800w-portable-power-station-best-solar-generator-for-camping","price_usd":429,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/eb70s-716wh-800w-portable-power-station-best-solar-generator-for-camping","page":"https://ridgewatt.com/stations/bluetti-eb70s/"},{"id":"bluetti-ep500","brand":"BLUETTI","model":"EP500","model_no":null,"capacity_wh":5120,"ac_output_w":2000,"surge_w":4800,"chemistry":"LiFePO4","weight_lb":167,"solar_input_total_w":1200,"solar_inputs":"PV input 55-145V 20A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/ep500-2000w-5100wh-solar-generator","price_usd":2999,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/ep500-2000w-5100wh-solar-generator","page":"https://ridgewatt.com/stations/bluetti-ep500/"},{"id":"bluetti-ep500pro","brand":"BLUETTI","model":"EP500Pro","model_no":null,"capacity_wh":5100,"ac_output_w":3000,"surge_w":6000,"chemistry":"LiFePO4","weight_lb":182,"solar_input_total_w":2400,"solar_inputs":"PV input 12-150V 12A voc | PV input 12-150V 12A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/bluetti-ep500pro-home-battery-backup","price_usd":3499,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/bluetti-ep500pro-home-battery-backup","page":"https://ridgewatt.com/stations/bluetti-ep500pro/"},{"id":"bluetti-elite-10-mini","brand":"BLUETTI","model":"Elite 10 Mini","model_no":null,"capacity_wh":128,"ac_output_w":200,"surge_w":300,"chemistry":"LiFePO4","weight_lb":4,"solar_input_total_w":100,"solar_inputs":"Solar input 12-28V 8.2A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/elite-10-mini-portable-power-station","price_usd":119,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/elite-10-mini-portable-power-station","page":"https://ridgewatt.com/stations/bluetti-elite-10-mini/"},{"id":"bluetti-elite-30-v2","brand":"BLUETTI","model":"Elite 30 V2","model_no":null,"capacity_wh":288,"ac_output_w":600,"surge_w":1500,"chemistry":"LiFePO4","weight_lb":9.5,"solar_input_total_w":200,"solar_inputs":"Solar input 12-28V 10A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/elite-30-v2-portable-power-station","price_usd":289.99,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/elite-30-v2-portable-power-station","page":"https://ridgewatt.com/stations/bluetti-elite-30-v2/"},{"id":"bluetti-elite-100-v2","brand":"BLUETTI","model":"Elite 100 V2","model_no":null,"capacity_wh":1024,"ac_output_w":1800,"surge_w":3600,"chemistry":"LiFePO4","weight_lb":25,"solar_input_total_w":1000,"solar_inputs":"Solar input 12-60V 20A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/elite-100-v2-portable-power-station","price_usd":489,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/elite-100-v2-portable-power-station","page":"https://ridgewatt.com/stations/bluetti-elite-100-v2/"},{"id":"bluetti-elite-100-mini","brand":"BLUETTI","model":"Elite 100 mini","model_no":null,"capacity_wh":1004.8,"ac_output_w":700,"surge_w":1050,"chemistry":"LiFePO4","weight_lb":23.6,"solar_input_total_w":350,"solar_inputs":"DC input 12-60V 10A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/elite-100-mini-portable-power-station","price_usd":429,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/elite-100-mini-portable-power-station","page":"https://ridgewatt.com/stations/bluetti-elite-100-mini/"},{"id":"bluetti-elite-200-v2","brand":"BLUETTI","model":"Elite 200 V2","model_no":null,"capacity_wh":2073.6,"ac_output_w":2600,"surge_w":null,"chemistry":"LiFePO4","weight_lb":53.4,"solar_input_total_w":1000,"solar_inputs":"Solar input 12-60V 20A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/elite-200-v2-portable-power-station","price_usd":899,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/elite-200-v2-portable-power-station","page":"https://ridgewatt.com/stations/bluetti-elite-200-v2/"},{"id":"bluetti-elite-300","brand":"BLUETTI","model":"Elite 300","model_no":null,"capacity_wh":3014.4,"ac_output_w":2400,"surge_w":4800,"chemistry":"LiFePO4","weight_lb":58,"solar_input_total_w":1200,"solar_inputs":"Solar input 12-60V 22A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/elite-300-portable-power-station","price_usd":1699,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/elite-300-portable-power-station","page":"https://ridgewatt.com/stations/bluetti-elite-300/"},{"id":"bluetti-elite-400","brand":"BLUETTI","model":"Elite 400","model_no":null,"capacity_wh":3840,"ac_output_w":2600,"surge_w":5200,"chemistry":"LiFePO4","weight_lb":86,"solar_input_total_w":1000,"solar_inputs":"Solar input 12-60V 20A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/elite-400-portable-power-station","price_usd":1399,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/elite-400-portable-power-station","page":"https://ridgewatt.com/stations/bluetti-elite-400/"},{"id":"bluetti-handsfree-1","brand":"BLUETTI","model":"Handsfree 1","model_no":null,"capacity_wh":268.8,"ac_output_w":300,"surge_w":null,"chemistry":"LiFePO4","weight_lb":11,"solar_input_total_w":200,"solar_inputs":"Solar input 12-28V 8.2A voc","source_type":"manual","source_url":"https://s4.bluettipower.com/bluetti_lgf/support/2025/05/a715bd38-6121-4d76-83b5-56d186f47205.pdf","price_usd":209,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/handsfree1-portable-backpack-power","page":"https://ridgewatt.com/stations/bluetti-handsfree-1/"},{"id":"bluetti-handsfree-2","brand":"BLUETTI","model":"Handsfree 2","model_no":null,"capacity_wh":512,"ac_output_w":700,"surge_w":null,"chemistry":"LiFePO4","weight_lb":16.5,"solar_input_total_w":350,"solar_inputs":"Solar input ?-?V ?A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/bluetti-handsfree-2-backpack-powerstation","price_usd":349,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/bluetti-handsfree-2-backpack-powerstation","page":"https://ridgewatt.com/stations/bluetti-handsfree-2/"},{"id":"bluetti-ps72","brand":"BLUETTI","model":"PS72","model_no":null,"capacity_wh":716,"ac_output_w":700,"surge_w":1400,"chemistry":"LiFePO4","weight_lb":21.4,"solar_input_total_w":200,"solar_inputs":"Solar input 12-28V ?A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/bluetti-ps72-portable-power-station-700w-716wh","price_usd":329,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/bluetti-ps72-portable-power-station-700w-716wh","page":"https://ridgewatt.com/stations/bluetti-ps72/"},{"id":"bluetti-pioneer-na","brand":"BLUETTI","model":"Pioneer Na","model_no":null,"capacity_wh":900,"ac_output_w":1500,"surge_w":null,"chemistry":"Sodium-ion","weight_lb":35.3,"solar_input_total_w":500,"solar_inputs":"Solar input 12-60V 10A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/sodium-ion-battery-pioneer-na","price_usd":899,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/sodium-ion-battery-pioneer-na","page":"https://ridgewatt.com/stations/bluetti-pioneer-na/"},{"id":"bluetti-premium-100-v2","brand":"BLUETTI","model":"Premium 100 V2","model_no":null,"capacity_wh":1024,"ac_output_w":1800,"surge_w":3600,"chemistry":"LiFePO4","weight_lb":25.3,"solar_input_total_w":1000,"solar_inputs":"DC input 12-60V 20A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/bluetti-premium-100-v2-portable-power-station","price_usd":849,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/bluetti-premium-100-v2-portable-power-station","page":"https://ridgewatt.com/stations/bluetti-premium-100-v2/"},{"id":"bluetti-premium-200-v2","brand":"BLUETTI","model":"Premium 200 V2","model_no":null,"capacity_wh":2073.6,"ac_output_w":2700,"surge_w":null,"chemistry":null,"weight_lb":null,"solar_input_total_w":1000,"solar_inputs":"PV input 12-60V 20A voc","source_type":"official product page","source_url":"https://www.bluettipower.com/products/bluetti-premium-200-v2-portable-power-station","price_usd":1549,"price_checked":"Oct 28, 2026","store_url":"https://www.bluettipower.com/products/bluetti-premium-200-v2-portable-power-station","page":"https://ridgewatt.com/stations/bluetti-premium-200-v2/"},{"id":"anker-solix-c200-dc","brand":"Anker SOLIX","model":"C200 DC","model_no":null,"capacity_wh":192,"ac_output_w":null,"surge_w":null,"chemistry":"LiFePO4","weight_lb":4.2,"solar_input_total_w":100,"solar_inputs":"XT60 11-28V 8.2A unspecified","source_type":"manual","source_url":"https://cdn.shopify.com/s/files/1/0493/9834/9974/files/A1727_V2_EN_UM_Web_20241031.pdf","price_usd":149.99,"price_checked":"Oct 28, 2026","store_url":"https://www.ankersolix.com/products/c200-dc","page":"https://ridgewatt.com/stations/anker-solix-c200-dc/"},{"id":"anker-solix-c200x-dc","brand":"Anker SOLIX","model":"C200X DC","model_no":null,"capacity_wh":192,"ac_output_w":null,"surge_w":null,"chemistry":null,"weight_lb":null,"solar_input_total_w":null,"solar_inputs":"Solar input ?-?V ?A unspecified","source_type":"official product page","source_url":"https://www.ankersolix.com/products/a1729011","price_usd":149.99,"price_checked":"Oct 28, 2026","store_url":"https://www.ankersolix.com/products/a1729011","page":"https://ridgewatt.com/stations/anker-solix-c200x-dc/"},{"id":"anker-solix-c200x","brand":"Anker SOLIX","model":"C200X","model_no":null,"capacity_wh":230,"ac_output_w":300,"surge_w":600,"chemistry":"LiFePO4","weight_lb":null,"solar_input_total_w":100,"solar_inputs":"XT60 11-28V ?A unspecified","source_type":"official product page","source_url":"https://www.ankersolix.com/products/a1725111","price_usd":299.99,"price_checked":"Oct 28, 2026","store_url":"https://www.ankersolix.com/products/a1725111","page":"https://ridgewatt.com/stations/anker-solix-c200x/"},{"id":"anker-solix-c300","brand":"Anker SOLIX","model":"C300","model_no":null,"capacity_wh":288,"ac_output_w":300,"surge_w":600,"chemistry":"LiFePO4","weight_lb":9.1,"solar_input_total_w":100,"solar_inputs":"XT60 11-28V 8.2A unspecified","source_type":"manual","source_url":"https://cdn.shopify.com/s/files/1/0493/9834/9974/files/A1722_V1_US_EN_UM_Web_20240814.pdf","price_usd":429.99,"price_checked":"Oct 28, 2026","store_url":"https://www.ankersolix.com/products/c300","page":"https://ridgewatt.com/stations/anker-solix-c300/"},{"id":"anker-solix-c300-dc","brand":"Anker SOLIX","model":"C300 DC","model_no":null,"capacity_wh":288,"ac_output_w":null,"surge_w":null,"chemistry":"LiFePO4","weight_lb":6.2,"solar_input_total_w":100,"solar_inputs":"XT60 11-28V 8.2A unspecified","source_type":"manual","source_url":"https://cdn.shopify.com/s/files/1/0493/9834/9974/files/TEM_A1726_V1_EN_UM_Web_20240913.pdf","price_usd":349.99,"price_checked":"Oct 28, 2026","store_url":"https://www.ankersolix.com/products/c300-dc","page":"https://ridgewatt.com/stations/anker-solix-c300-dc/"},{"id":"anker-solix-c300x","brand":"Anker SOLIX","model":"C300X","model_no":null,"capacity_wh":288,"ac_output_w":300,"surge_w":600,"chemistry":"LiFePO4","weight_lb":9.1,"solar_input_total_w":100,"solar_inputs":"XT60 11-28V 8.2A unspecified","source_type":"manual","source_url":"https://support.ankersolix.com/s/article/Anker-SOLIX-C300X-Portable-Power-Station-User-Guide-A1723-US","price_usd":299.99,"price_checked":"Oct 28, 2026","store_url":"https://www.ankersolix.com/products/c300x-portable-power-station-us","page":"https://ridgewatt.com/stations/anker-solix-c300x/"},{"id":"anker-solix-c1000x-gen-2","brand":"Anker SOLIX","model":"C1000X Gen 2","model_no":null,"capacity_wh":1024,"ac_output_w":2000,"surge_w":2400,"chemistry":null,"weight_lb":24.9,"solar_input_total_w":600,"solar_inputs":"XT60i 11-60V 14.5A voc","source_type":"manual","source_url":"https://support.ankersolix.com/s/article/Anker-SOLIX-C1000X-Gen-2-Portable-Power-Station-User-Guide-A1765","price_usd":699.99,"price_checked":"Oct 28, 2026","store_url":"https://www.ankersolix.com/products/c1000x-gen-2-portable-power-station-us","page":"https://ridgewatt.com/stations/anker-solix-c1000x-gen-2/"},{"id":"anker-solix-c1000x","brand":"Anker SOLIX","model":"C1000X","model_no":null,"capacity_wh":1056,"ac_output_w":1800,"surge_w":2400,"chemistry":"LiFePO4","weight_lb":28.4,"solar_input_total_w":600,"solar_inputs":"XT60 11-60V 12.5A unspecified","source_type":"official product page","source_url":"https://www.ankersolix.com/products/a1761111","price_usd":599.99,"price_checked":"Oct 28, 2026","store_url":"https://www.ankersolix.com/products/a1761111","page":"https://ridgewatt.com/stations/anker-solix-c1000x/"},{"id":"anker-solix-c2000-gen-2","brand":"Anker SOLIX","model":"C2000 Gen 2","model_no":null,"capacity_wh":2048,"ac_output_w":2400,"surge_w":4000,"chemistry":"LiFePO4","weight_lb":41.7,"solar_input_total_w":800,"solar_inputs":"Solar input 11-60V 17A unspecified","source_type":"official product page","source_url":"https://www.ankersolix.com/products/c2000-gen2","price_usd":1199.99,"price_checked":"Oct 28, 2026","store_url":"https://www.ankersolix.com/products/c2000-gen2","page":"https://ridgewatt.com/stations/anker-solix-c2000-gen-2/"},{"id":"anker-solix-f1500","brand":"Anker SOLIX","model":"F1500","model_no":null,"capacity_wh":1536,"ac_output_w":1800,"surge_w":2520,"chemistry":"LiFePO4","weight_lb":42.1,"solar_input_total_w":600,"solar_inputs":"XT60 11-30V 12.5A unspecified","source_type":"official product page","source_url":"https://www.ankersolix.com/products/f1500","price_usd":1199.99,"price_checked":"Oct 28, 2026","store_url":"https://www.ankersolix.com/products/f1500","page":"https://ridgewatt.com/stations/anker-solix-f1500/"},{"id":"anker-solix-f2600","brand":"Anker SOLIX","model":"F2600","model_no":null,"capacity_wh":2560,"ac_output_w":2400,"surge_w":2800,"chemistry":"LiFePO4","weight_lb":69.7,"solar_input_total_w":1000,"solar_inputs":"Solar input 11-60V 20A unspecified","source_type":"official product page","source_url":"https://www.ankersolix.com/products/f2600","price_usd":1999.99,"price_checked":"Oct 28, 2026","store_url":"https://www.ankersolix.com/products/f2600","page":"https://ridgewatt.com/stations/anker-solix-f2600/"},{"id":"anker-solix-f3000","brand":"Anker SOLIX","model":"F3000","model_no":null,"capacity_wh":3072,"ac_output_w":3600,"surge_w":7200,"chemistry":"LiFePO4","weight_lb":91.5,"solar_input_total_w":2400,"solar_inputs":"High-PV 11-165V 17A unspecified | Low-PV 11-60V 17A unspecified","source_type":"official product page","source_url":"https://www.ankersolix.com/products/f3000","price_usd":1899.99,"price_checked":"Oct 28, 2026","store_url":"https://www.ankersolix.com/products/f3000","page":"https://ridgewatt.com/stations/anker-solix-f3000/"},{"id":"anker-solix-f3800-plus","brand":"Anker SOLIX","model":"F3800 Plus","model_no":null,"capacity_wh":3840,"ac_output_w":6000,"surge_w":9000,"chemistry":"LiFePO4","weight_lb":132.3,"solar_input_total_w":3200,"solar_inputs":"Solar input 11-165V 17A unspecified | Solar input 11-165V 17A unspecified","source_type":"official product page","source_url":"https://www.ankersolix.com/products/f3800-plus","price_usd":2999.99,"price_checked":"Oct 28, 2026","store_url":"https://www.ankersolix.com/products/f3800-plus","page":"https://ridgewatt.com/stations/anker-solix-f3800-plus/"},{"id":"anker-solix-s2000","brand":"Anker SOLIX","model":"S2000","model_no":null,"capacity_wh":2010,"ac_output_w":1500,"surge_w":3000,"chemistry":"LiFePO4","weight_lb":35.7,"solar_input_total_w":400,"solar_inputs":"XT60i 11-60V 12.5A unspecified","source_type":"manual","source_url":"https://support.ankersolix.com/s/article/Anker-SOLIX-S2000-Portable-Power-Station-User-Guide-AS220-United-States","price_usd":999.99,"price_checked":"Oct 28, 2026","store_url":"https://www.ankersolix.com/products/s2000-portable-power-station","page":"https://ridgewatt.com/stations/anker-solix-s2000/"},{"id":"anker-solix-s5000","brand":"Anker SOLIX","model":"S5000","model_no":null,"capacity_wh":5024,"ac_output_w":4500,"surge_w":8000,"chemistry":"LiFePO4","weight_lb":97,"solar_input_total_w":3000,"solar_inputs":"Solar input ?-?V ?A unspecified","source_type":"official product page","source_url":"https://www.ankersolix.com/products/s5000-portable-power-station","price_usd":3599.99,"price_checked":"Oct 28, 2026","store_url":"https://www.ankersolix.com/products/s5000-portable-power-station","page":"https://ridgewatt.com/stations/anker-solix-s5000/"},{"id":"jackery-explorer-100-plus","brand":"Jackery","model":"Explorer 100 Plus","model_no":"JE-100A","capacity_wh":99.2,"ac_output_w":null,"surge_w":null,"chemistry":"LiFePO4","weight_lb":2.1,"solar_input_total_w":100,"solar_inputs":"USB-C 18-27.2V 5A unspecified","source_type":"manual","source_url":"https://cdn.shopify.com/s/files/1/0970/9262/files/Jackery_Explorer_100_Plus_User_Manual.pdf","price_usd":149,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/jackery-explorer-100-plus-portable-power-station","page":"https://ridgewatt.com/stations/jackery-explorer-100-plus/"},{"id":"jackery-explorer-240-v2","brand":"Jackery","model":"Explorer 240 v2","model_no":"JE-240A","capacity_wh":256,"ac_output_w":300,"surge_w":600,"chemistry":"LiFePO4","weight_lb":7.9,"solar_input_total_w":100,"solar_inputs":"USB-C (with DC8020-to-USB-C adapter) 12-27V 5A unspecified","source_type":"manual","source_url":"https://r.jackery.net/productGuide/Jackery%20Explorer%20240%20v2%20User%20Manual.pdf","price_usd":249,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/jackery-explorer-240-v2-portable-power-station","page":"https://ridgewatt.com/stations/jackery-explorer-240-v2/"},{"id":"jackery-explorer-300-v2","brand":"Jackery","model":"Explorer 300 v2","model_no":"JE-300C","capacity_wh":288,"ac_output_w":300,"surge_w":600,"chemistry":"LiFePO4","weight_lb":8.2,"solar_input_total_w":100,"solar_inputs":"DC8020 16-28V 6A voc","source_type":"manual","source_url":"https://cdn.shopify.com/s/files/1/0970/9262/files/Jackery_Explorer_300_v2_User_Manuals_compressed.pdf","price_usd":279,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/jackery-explorer-300-v2-portable-power-station","page":"https://ridgewatt.com/stations/jackery-explorer-300-v2/"},{"id":"jackery-explorer-300d","brand":"Jackery","model":"Explorer 300D","model_no":"JE-300D","capacity_wh":288,"ac_output_w":null,"surge_w":null,"chemistry":"LiFePO4","weight_lb":5.5,"solar_input_total_w":100,"solar_inputs":"DC8020 16-28V 6A voc","source_type":"manual","source_url":"https://cdn.shopify.com/s/files/1/0970/9262/files/USER_MANUAL_Jackery_Explorer_300D.pdf","price_usd":209,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/jackery-explorer-300d-portable-power-station","page":"https://ridgewatt.com/stations/jackery-explorer-300d/"},{"id":"jackery-explorer-300","brand":"Jackery","model":"Explorer 300","model_no":null,"capacity_wh":292,"ac_output_w":300,"surge_w":null,"chemistry":"LiFePO4","weight_lb":7.5,"solar_input_total_w":null,"solar_inputs":"Solar input ?-?V ?A unspecified","source_type":"official product page","source_url":"https://www.jackery.com/products/explorer-300-portable-power-station","price_usd":289,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/explorer-300-portable-power-station","page":"https://ridgewatt.com/stations/jackery-explorer-300/"},{"id":"jackery-explorer-600-v2","brand":"Jackery","model":"Explorer 600 v2","model_no":"JE-600A","capacity_wh":640,"ac_output_w":500,"surge_w":1000,"chemistry":"LiFePO4","weight_lb":14.1,"solar_input_total_w":200,"solar_inputs":"DC8020 16-60V 10.5A unspecified","source_type":"manual","source_url":"https://faq.jackery.com/hc/en-us/articles/52303598063643-Explorer-600-V2-Basic-Information","price_usd":499,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/jackery-explorer-600-v2-portable-power-station","page":"https://ridgewatt.com/stations/jackery-explorer-600-v2/"},{"id":"jackery-explorer-1000","brand":"Jackery","model":"Explorer 1000","model_no":null,"capacity_wh":1002,"ac_output_w":1000,"surge_w":2000,"chemistry":"Li-ion","weight_lb":22,"solar_input_total_w":null,"solar_inputs":"DC input 12-30V 7.5A unspecified","source_type":"official product page","source_url":"https://www.jackery.com/products/explorer-1000-portable-power-station","price_usd":999,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/explorer-1000-portable-power-station","page":"https://ridgewatt.com/stations/jackery-explorer-1000/"},{"id":"jackery-explorer-1000-plus","brand":"Jackery","model":"Explorer 1000 Plus","model_no":"JE-1000C","capacity_wh":1264.64,"ac_output_w":2000,"surge_w":4000,"chemistry":"LiFePO4","weight_lb":32,"solar_input_total_w":800,"solar_inputs":"DC8020 12-60V 11A working | DC8020 12-60V 11A working","source_type":"manual","source_url":"https://r.jackery.net/productGuide/Jackery%20Explorer%201000%20Plus%20User%20Manual.pdf","price_usd":619,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/jackery-explorer-1000-plus-portable-power-station","page":"https://ridgewatt.com/stations/jackery-explorer-1000-plus/"},{"id":"jackery-explorer-1500-v2","brand":"Jackery","model":"Explorer 1500 v2","model_no":"JE-1500D","capacity_wh":1536,"ac_output_w":2000,"surge_w":4000,"chemistry":"LiFePO4","weight_lb":32,"solar_input_total_w":400,"solar_inputs":"DC8020 16-60V 12A voc | DC8020 16-60V 12A voc","source_type":"manual","source_url":"https://cdn.shopify.com/s/files/1/0970/9262/files/Jackery_Explorer_1500_User_Manual_e02af3b9-e015-4547-ab8e-b004d1d19c3a.pdf","price_usd":849,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/jackery-explorer-1500-v2-portable-power-station","page":"https://ridgewatt.com/stations/jackery-explorer-1500-v2/"},{"id":"jackery-explorer-1500-ultra","brand":"Jackery","model":"Explorer 1500 Ultra","model_no":"JE-1500C","capacity_wh":1536,"ac_output_w":1800,"surge_w":3600,"chemistry":"LiFePO4","weight_lb":38.6,"solar_input_total_w":800,"solar_inputs":"DC8020 16-60V 12A voc | DC8020 16-60V 12A voc","source_type":"manual","source_url":"https://cdn.shopify.com/s/files/1/0970/9262/files/Jackery_Explorer_1500_Ultra_USER_MANUAL.pdf","price_usd":1079,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/jackery-explorer-1500-ultra-portable-power-station","page":"https://ridgewatt.com/stations/jackery-explorer-1500-ultra/"},{"id":"jackery-explorer-2000-v2","brand":"Jackery","model":"Explorer 2000 v2","model_no":"JE-2000D","capacity_wh":2042,"ac_output_w":2200,"surge_w":4400,"chemistry":"LiFePO4","weight_lb":39.5,"solar_input_total_w":400,"solar_inputs":"DC8020 11-60V 12A unspecified | DC8020 11-60V 12A unspecified","source_type":"manual","source_url":"https://r.jackery.net/productGuide/Jackery%20Explorer%202000%20v2%20User%20Manual.pdf","price_usd":999,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/jackery-explorer-2000-v2-portable-power-station","page":"https://ridgewatt.com/stations/jackery-explorer-2000-v2/"},{"id":"jackery-explorer-5000-plus","brand":"Jackery","model":"Explorer 5000 Plus","model_no":"JE-5000A","capacity_wh":5040,"ac_output_w":7200,"surge_w":14400,"chemistry":"LiFePO4","weight_lb":134.5,"solar_input_total_w":null,"solar_inputs":"High-PV (MC4) 135-450V 15A unspecified | Low-PV (DC8020) 11-60V 10.5A working | Low-PV (DC8020) 11-60V 10.5A working","source_type":"manual","source_url":"https://r.jackery.net/productGuide/Explorer%205000%20Plus%20User%20Manual-US.pdf","price_usd":3499,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/jackery-explorer-5000-plus","page":"https://ridgewatt.com/stations/jackery-explorer-5000-plus/"},{"id":"jackery-homepower-1000-v2","brand":"Jackery","model":"HomePower 1000 v2","model_no":"JHP-1000A","capacity_wh":1024,"ac_output_w":1500,"surge_w":3000,"chemistry":"LiFePO4","weight_lb":23.4,"solar_input_total_w":400,"solar_inputs":"DC8020 16-60V 12A unspecified | DC8020 16-60V 12A unspecified","source_type":"manual","source_url":"https://faq.jackery.com/hc/en-us/articles/57131002838299-HomePower-1000-V2-Basic-Information","price_usd":549,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/jackery-homepower-1000-v2","page":"https://ridgewatt.com/stations/jackery-homepower-1000-v2/"},{"id":"jackery-homepower-1000-plus-v2","brand":"Jackery","model":"HomePower 1000 Plus v2","model_no":"JHP-1000B","capacity_wh":1024,"ac_output_w":1800,"surge_w":3600,"chemistry":null,"weight_lb":23.8,"solar_input_total_w":400,"solar_inputs":"DC8020 16-60V 12A unspecified | DC8020 16-60V 12A unspecified","source_type":"manual","source_url":"https://faq.jackery.com/hc/en-us/articles/57133065005211-HomePower-1000-Plus-V2-Basic-Information","price_usd":699,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/jackery-homepower-1000-plus-v2","page":"https://ridgewatt.com/stations/jackery-homepower-1000-plus-v2/"},{"id":"jackery-homepower-2000-plus-v2","brand":"Jackery","model":"HomePower 2000 Plus v2","model_no":"JHP-2000A","capacity_wh":2048,"ac_output_w":2400,"surge_w":4800,"chemistry":"LiFePO4","weight_lb":41.4,"solar_input_total_w":800,"solar_inputs":"DC8020 16-60V 12A unspecified | DC8020 16-60V 12A unspecified","source_type":"manual","source_url":"https://faq.jackery.com/hc/en-us/articles/52303728405147-HomePower-2000-Plus-V2-Basic-Information","price_usd":1199,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/jackery-homepower-2000-plus-v2","page":"https://ridgewatt.com/stations/jackery-homepower-2000-plus-v2/"},{"id":"jackery-homepower-3000","brand":"Jackery","model":"HomePower 3000","model_no":"JHP-3000C","capacity_wh":3072,"ac_output_w":3600,"surge_w":7200,"chemistry":"LiFePO4","weight_lb":59.5,"solar_input_total_w":1000,"solar_inputs":"DC8020 12-60V 12A working | DC8020 12-60V 12A working","source_type":"manual","source_url":"https://cdn.shopify.com/s/files/1/0970/9262/files/Jackery_HomePower_3000_User_Manual_d7e442c7-e1aa-4845-910b-8d6f7f3a793f.pdf","price_usd":1499,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/jackery-homepower-3000","page":"https://ridgewatt.com/stations/jackery-homepower-3000/"},{"id":"jackery-homepower-3600-plus","brand":"Jackery","model":"HomePower 3600 Plus","model_no":"JHP-3600A","capacity_wh":3584,"ac_output_w":3600,"surge_w":7200,"chemistry":"LiFePO4","weight_lb":77.2,"solar_input_total_w":1000,"solar_inputs":"DC8020 12-60V 12A voc | DC8020 12-60V 12A voc","source_type":"manual","source_url":"https://images.thdstatic.com/catalog/pdfImages/c3/c352c472-9950-45fc-bb00-258ef78b017b.pdf","price_usd":1899,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/jackery-homepower-3600-plus","page":"https://ridgewatt.com/stations/jackery-homepower-3600-plus/"},{"id":"jackery-homepower-3600-pro-max","brand":"Jackery","model":"HomePower 3600 Pro Max","model_no":"JHP-3600C","capacity_wh":3584,"ac_output_w":2000,"surge_w":4000,"chemistry":"LiFePO4","weight_lb":73.9,"solar_input_total_w":1200,"solar_inputs":"DC8020 16-60V 12A working | DC8020 16-60V 12A working","source_type":"manual","source_url":"https://faq.jackery.com/hc/en-us/articles/52303751654555-HomePower-3600-Pro-Max-Basic-Information","price_usd":2099,"price_checked":"Oct 28, 2026","store_url":"https://www.jackery.com/products/jackery-homepower-3600-pro-max","page":"https://ridgewatt.com/stations/jackery-homepower-3600-pro-max/"},{"id":"goalzero-yeti-300","brand":"Goal Zero","model":"Yeti 300","model_no":null,"capacity_wh":297,"ac_output_w":350,"surge_w":600,"chemistry":"LiFePO4","weight_lb":13.7,"solar_input_total_w":200,"solar_inputs":"8mm 12.3-28V 10A unspecified","source_type":"official product page","source_url":"https://goalzero.com/products/yeti-300-portable-power-station-lifepo4-battery","price_usd":349.95,"price_checked":"Oct 28, 2026","store_url":"https://goalzero.com/products/yeti-300-portable-power-station-lifepo4-battery","page":"https://ridgewatt.com/stations/goalzero-yeti-300/"},{"id":"goalzero-yeti-500","brand":"Goal Zero","model":"Yeti 500","model_no":null,"capacity_wh":499.2,"ac_output_w":500,"surge_w":1000,"chemistry":"LiFePO4","weight_lb":16.1,"solar_input_total_w":200,"solar_inputs":"8mm 12.3-28V 10A unspecified","source_type":"official product page","source_url":"https://goalzero.com/products/yeti-500-portable-power-station-lfp-battery","price_usd":499.95,"price_checked":"Oct 28, 2026","store_url":"https://goalzero.com/products/yeti-500-portable-power-station-lfp-battery","page":"https://ridgewatt.com/stations/goalzero-yeti-500/"},{"id":"goalzero-yeti-700","brand":"Goal Zero","model":"Yeti 700","model_no":null,"capacity_wh":677.37,"ac_output_w":600,"surge_w":1000,"chemistry":"LiFePO4","weight_lb":20.3,"solar_input_total_w":200,"solar_inputs":"8mm 12.3-28V 10A unspecified","source_type":"official product page","source_url":"https://goalzero.com/products/yeti-700-portable-power-station-lfp-batteries","price_usd":699.95,"price_checked":"Oct 28, 2026","store_url":"https://goalzero.com/products/yeti-700-portable-power-station-lfp-batteries","page":"https://ridgewatt.com/stations/goalzero-yeti-700/"},{"id":"goalzero-yeti-1500","brand":"Goal Zero","model":"Yeti 1500","model_no":null,"capacity_wh":1505.28,"ac_output_w":2000,"surge_w":3600,"chemistry":"LiFePO4","weight_lb":52.75,"solar_input_total_w":900,"solar_inputs":"HPP 12.3-60V 20A unspecified | 8mm 13.2-30V 10A unspecified","source_type":"official product page","source_url":"https://goalzero.com/products/yeti-1500-portable-power-station-lifepo4-battery","price_usd":1499.95,"price_checked":"Oct 28, 2026","store_url":"https://goalzero.com/products/yeti-1500-portable-power-station-lifepo4-battery","page":"https://ridgewatt.com/stations/goalzero-yeti-1500/"},{"id":"goalzero-yeti-pro-4000","brand":"Goal Zero","model":"Yeti PRO 4000","model_no":null,"capacity_wh":3994,"ac_output_w":3600,"surge_w":7200,"chemistry":"LiFePO4","weight_lb":115.7,"solar_input_total_w":3000,"solar_inputs":"HPP 13.3-150V 30A unspecified | 8mm 12.3-28V 10A unspecified","source_type":"official product page","source_url":"https://goalzero.com/products/yeti-pro-4000-power-station","price_usd":3999.95,"price_checked":"Oct 28, 2026","store_url":"https://goalzero.com/products/yeti-pro-4000-power-station","page":"https://ridgewatt.com/stations/goalzero-yeti-pro-4000/"},{"id":"goalzero-yeti-1000x","brand":"Goal Zero","model":"Yeti 1000X","model_no":null,"capacity_wh":997,"ac_output_w":1500,"surge_w":3500,"chemistry":"NMC","weight_lb":31.68,"solar_input_total_w":600,"solar_inputs":"High Power Port 14-50V 50A unspecified | 8mm 14-50V 10A unspecified","source_type":"official product page","source_url":"https://goalzero.com/products/goal-zero-yeti-1000x-portable-power-station","price_usd":999.95,"price_checked":"Oct 28, 2026","store_url":"https://goalzero.com/products/goal-zero-yeti-1000x-portable-power-station","page":"https://ridgewatt.com/stations/goalzero-yeti-1000x/"},{"id":"goalzero-yeti-1500x","brand":"Goal Zero","model":"Yeti 1500X","model_no":null,"capacity_wh":1516,"ac_output_w":2000,"surge_w":3500,"chemistry":"NMC","weight_lb":45.64,"solar_input_total_w":600,"solar_inputs":"High Power Port 14-50V 50A unspecified | 8mm 14-50V 10A unspecified","source_type":"official product page","source_url":"https://goalzero.com/products/goal-zero-yeti-1500x-portable-power-station","price_usd":1124.89,"price_checked":"Oct 28, 2026","store_url":"https://goalzero.com/products/goal-zero-yeti-1500x-portable-power-station","page":"https://ridgewatt.com/stations/goalzero-yeti-1500x/"},{"id":"goalzero-yeti-3000x","brand":"Goal Zero","model":"Yeti 3000X","model_no":null,"capacity_wh":3032,"ac_output_w":2000,"surge_w":3500,"chemistry":"NMC","weight_lb":69.78,"solar_input_total_w":600,"solar_inputs":"High Power Port 14-50V 50A unspecified | 8mm 14-50V 10A unspecified","source_type":"official product page","source_url":"https://goalzero.com/products/goal-zero-yeti-3000x-portable-power-station","price_usd":2999.95,"price_checked":"Oct 28, 2026","store_url":"https://goalzero.com/products/goal-zero-yeti-3000x-portable-power-station","page":"https://ridgewatt.com/stations/goalzero-yeti-3000x/"},{"id":"goalzero-yeti-6000x","brand":"Goal Zero","model":"Yeti 6000X","model_no":null,"capacity_wh":6071,"ac_output_w":2000,"surge_w":3500,"chemistry":"NMC","weight_lb":106,"solar_input_total_w":600,"solar_inputs":"High Power Port 14-50V 50A unspecified | 8mm 14-50V 10A unspecified","source_type":"official product page","source_url":"https://goalzero.com/products/goal-zero-yeti-6000x-portable-power-station","price_usd":3999.95,"price_checked":"Oct 28, 2026","store_url":"https://goalzero.com/products/goal-zero-yeti-6000x-portable-power-station","page":"https://ridgewatt.com/stations/goalzero-yeti-6000x/"},{"id":"goalzero-yeti-500x","brand":"Goal Zero","model":"Yeti 500X","model_no":null,"capacity_wh":497,"ac_output_w":300,"surge_w":1200,"chemistry":"NMC","weight_lb":12.9,"solar_input_total_w":150,"solar_inputs":"8mm 13-22V 10A unspecified","source_type":"official product page","source_url":"https://goalzero.com/products/goal-zero-yeti-500x-portable-power-station","price_usd":499.95,"price_checked":"Oct 28, 2026","store_url":"https://goalzero.com/products/goal-zero-yeti-500x-portable-power-station","page":"https://ridgewatt.com/stations/goalzero-yeti-500x/"},{"id":"goalzero-yeti-200x","brand":"Goal Zero","model":"Yeti 200X","model_no":null,"capacity_wh":187,"ac_output_w":120,"surge_w":200,"chemistry":"NMC","weight_lb":5,"solar_input_total_w":100,"solar_inputs":"8mm 13-22V 7A unspecified","source_type":"official product page","source_url":"https://goalzero.com/products/goal-zero-yeti-200x-portable-power-station","price_usd":219.95,"price_checked":"Oct 28, 2026","store_url":"https://goalzero.com/products/goal-zero-yeti-200x-portable-power-station","page":"https://ridgewatt.com/stations/goalzero-yeti-200x/"},{"id":"dji-power-500","brand":"DJI","model":"Power 500","model_no":"DYM500L","capacity_wh":512,"ac_output_w":1000,"surge_w":null,"chemistry":"LiFePO4","weight_lb":16.1,"solar_input_total_w":300,"solar_inputs":"XT60, Solar Panel Adapter Module channel 1 12-30V 10A voc | XT60, Solar Panel Adapter Module channel 2 12-30V 10A voc | XT60, Solar Panel Adapter Module channel 3 12-30V 10A voc","source_type":"official product page","source_url":"https://store.dji.com/product/dji-power-solar-panel-adapter-module-mppt","price_usd":null,"price_checked":"Oct 28, 2026","store_url":"https://store.dji.com/product/dji-power-500","page":"https://ridgewatt.com/stations/dji-power-500/"},{"id":"dji-power-1000","brand":"DJI","model":"Power 1000","model_no":"DYM1000L","capacity_wh":1024,"ac_output_w":2200,"surge_w":4400,"chemistry":"LiFePO4","weight_lb":28.7,"solar_input_total_w":400,"solar_inputs":"XT60, Solar Panel Adapter Module channel 1 12-30V 10A voc | XT60, Solar Panel Adapter Module channel 2 12-30V 10A voc | XT60, Solar Panel Adapter Module channel 3 12-30V 10A voc","source_type":"official product page","source_url":"https://store.dji.com/product/dji-power-solar-panel-adapter-module-mppt","price_usd":null,"price_checked":"Oct 28, 2026","store_url":"https://store.dji.com/product/dji-power-1000","page":"https://ridgewatt.com/stations/dji-power-1000/"},{"id":"dji-power-2000","brand":"DJI","model":"Power 2000","model_no":"DYM2000L","capacity_wh":2048,"ac_output_w":3000,"surge_w":null,"chemistry":"LiFePO4","weight_lb":48.5,"solar_input_total_w":400,"solar_inputs":"XT60, Solar Panel Adapter Module channel 1 12-30V 10A voc | XT60, Solar Panel Adapter Module channel 2 12-30V 10A voc | XT60, Solar Panel Adapter Module channel 3 12-30V 10A voc","source_type":"official product page","source_url":"https://store.dji.com/product/dji-power-solar-panel-adapter-module-mppt","price_usd":null,"price_checked":"Oct 28, 2026","store_url":"https://store.dji.com/product/dji-power-2000","page":"https://ridgewatt.com/stations/dji-power-2000/"},{"id":"dji-power-1000-mini","brand":"DJI","model":"Power 1000 Mini","model_no":"DYM1000M","capacity_wh":1008,"ac_output_w":800,"surge_w":null,"chemistry":"LiFePO4","weight_lb":25.4,"solar_input_total_w":400,"solar_inputs":"SDC (built-in MPPT, DJI MC4 solar cable) 9-28V ?A unspecified","source_type":"official product page","source_url":"https://www.dji.com/power-1000-mini/faq","price_usd":null,"price_checked":"Oct 28, 2026","store_url":"https://www.dji.com/power-1000-mini","page":"https://ridgewatt.com/stations/dji-power-1000-mini/"}],"panels":[{"id":"jackery-solarsaga-200-js200e","brand":"Jackery","model":"SolarSaga 200","model_no":"JS-200E","type":"portable","rated_w":200,"voc_v":22,"isc_a":12.5,"vmp_v":18,"imp_a":11.5,"voc_temp_coeff_pct_per_c":-0.27,"connector":"DC8020 male (cable has DC8020-to-DC7909 adapter)","weight_lb":null,"source_type":"manual","source_url":"https://www.mrsolar.com/content/pdf/jackery/Jackery_SolarSaga_200_User_Manual_-_666E.pdf","price_usd":379,"store_url":"https://www.jackery.com/products/solarsaga-200w-solar-panel","page":"https://ridgewatt.com/panels/jackery-solarsaga-200-js200e/"},{"id":"jackery-solarsaga-200-js200d","brand":"Jackery","model":"SolarSaga 200","model_no":"JS-200D","type":"portable","rated_w":200,"voc_v":24.8,"isc_a":11.2,"vmp_v":20,"imp_a":10,"voc_temp_coeff_pct_per_c":-0.268,"connector":"DC8020 male","weight_lb":null,"source_type":"manual","source_url":"https://pvundso.de/Doku/Jackery/Jackery_SolarSaga_200W_Benutzerhandbuch.pdf","price_usd":null,"store_url":null,"page":"https://ridgewatt.com/panels/jackery-solarsaga-200-js200d/"},{"id":"ecoflow-400w-portable","brand":"EcoFlow","model":"400W Portable Solar Panel","model_no":null,"type":"portable","rated_w":400,"voc_v":48,"isc_a":11,"vmp_v":41,"imp_a":9.8,"voc_temp_coeff_pct_per_c":null,"connector":"Solar connector (MC4)","weight_lb":null,"source_type":"retailer listing","source_url":"https://www.cliftoncameras.co.uk/uploads/specifications/EcoFlow%20400W%20Portable%20Solar%20Panel%20Specifications.pdf","price_usd":599,"store_url":"https://us.ecoflow.com/products/400w-portable-solar-panel","page":"https://ridgewatt.com/panels/ecoflow-400w-portable/"},{"id":"ecoflow-220w-bifacial-nextgen","brand":"EcoFlow","model":"NextGen 220W Bifacial Portable Solar Panel","model_no":null,"type":"portable","rated_w":220,"voc_v":21.5,"isc_a":12.4,"vmp_v":18.4,"imp_a":11.9,"voc_temp_coeff_pct_per_c":null,"connector":"Photovoltaic connectors (MC4)","weight_lb":null,"source_type":"official product page","source_url":"https://us.ecoflow.com/products/220w-bifacial-portable-solar-panel","price_usd":399,"store_url":"https://us.ecoflow.com/products/nextgen-220w-bifacial-portable-solar-panel","page":"https://ridgewatt.com/panels/ecoflow-220w-bifacial-nextgen/"},{"id":"bluetti-pv200d","brand":"BLUETTI","model":"PV200D","model_no":"PV200D","type":"portable","rated_w":200,"voc_v":24.6,"isc_a":10.8,"vmp_v":20.4,"imp_a":9.7,"voc_temp_coeff_pct_per_c":null,"connector":null,"weight_lb":17.15,"source_type":"manual","source_url":"https://www.bluettipower.com.au/products/bluetti-pv200d-solar-panel-200w","price_usd":null,"store_url":null,"page":"https://ridgewatt.com/panels/bluetti-pv200d/"},{"id":"bluetti-pv350d","brand":"BLUETTI","model":"PV350D","model_no":"PV350D","type":"portable","rated_w":350,"voc_v":33,"isc_a":13.8,"vmp_v":27.6,"imp_a":12.7,"voc_temp_coeff_pct_per_c":null,"connector":null,"weight_lb":29.1,"source_type":"manual","source_url":"https://s4.bluettipower.com/bluetti_lgf/support/2025/05/99f74f2d-b02c-4dd5-bd38-879deccba932.pdf","price_usd":null,"store_url":null,"page":"https://ridgewatt.com/panels/bluetti-pv350d/"},{"id":"anker-solix-ps100","brand":"Anker SOLIX","model":"PS100 Bifacial","model_no":null,"type":"portable","rated_w":100,"voc_v":25.9,"isc_a":4.86,"vmp_v":21.6,"imp_a":4.63,"voc_temp_coeff_pct_per_c":null,"connector":"Solar charging cables + 0.5m XT60i cable included","weight_lb":null,"source_type":"retailer listing","source_url":"https://www.alza.hu/EN/anker-solix-ps100-bifacial-portable-solar-panel-d13164588.htm","price_usd":299.99,"store_url":"https://www.ankersolix.com/products/100w-bifacial-portable-solar-panel","page":"https://ridgewatt.com/panels/anker-solix-ps100/"},{"id":"anker-solix-ps200","brand":"Anker SOLIX","model":"PS200 Bifacial","model_no":null,"type":"portable","rated_w":200,"voc_v":57.6,"isc_a":4.38,"vmp_v":48,"imp_a":4.16,"voc_temp_coeff_pct_per_c":null,"connector":null,"weight_lb":null,"source_type":"retailer listing","source_url":"https://www.alza.hu/EN/anker-solix-ps200-bifacial-portable-solar-panel-d13164590.htm","price_usd":499.99,"store_url":"https://www.ankersolix.com/products/ps200-bifacial-portable-solar-panel","page":"https://ridgewatt.com/panels/anker-solix-ps200/"},{"id":"ecoflow-100w-rigid","brand":"EcoFlow","model":"100W Rigid Solar Panel","model_no":null,"type":"rigid","rated_w":100,"voc_v":20.3,"isc_a":6.3,"vmp_v":17.1,"imp_a":5.9,"voc_temp_coeff_pct_per_c":-0.33,"connector":"Solar connector","weight_lb":13.7,"source_type":"official product page","source_url":"https://us.ecoflow.com/products/100w-rigid-solar-panel","price_usd":139,"store_url":"https://us.ecoflow.com/products/100w-rigid-solar-panel","page":"https://ridgewatt.com/panels/ecoflow-100w-rigid/"},{"id":"ecoflow-100w-flexible","brand":"EcoFlow","model":"100W Flexible Solar Panel","model_no":null,"type":"flexible","rated_w":100,"voc_v":20.3,"isc_a":6.3,"vmp_v":17.1,"imp_a":5.9,"voc_temp_coeff_pct_per_c":-0.33,"connector":"Solar connector","weight_lb":5.1,"source_type":"official product page","source_url":"https://us.ecoflow.com/products/100w-flexible-solar-panel","price_usd":199,"store_url":"https://us.ecoflow.com/products/100w-flexible-solar-panel","page":"https://ridgewatt.com/panels/ecoflow-100w-flexible/"},{"id":"ecoflow-110w-portable","brand":"EcoFlow","model":"110W Portable Solar Panel","model_no":null,"type":"portable","rated_w":110,"voc_v":21.8,"isc_a":6.5,"vmp_v":18.4,"imp_a":6,"voc_temp_coeff_pct_per_c":null,"connector":"Solar connector","weight_lb":8.8,"source_type":"official product page","source_url":"https://us.ecoflow.com/products/110w-portable-solar-panel","price_usd":259,"store_url":"https://us.ecoflow.com/products/110w-portable-solar-panel","page":"https://ridgewatt.com/panels/ecoflow-110w-portable/"},{"id":"ecoflow-160w-nextgen","brand":"EcoFlow","model":"NextGen 160W Portable Solar Panel","model_no":null,"type":"portable","rated_w":160,"voc_v":21.3,"isc_a":9.1,"vmp_v":18.6,"imp_a":8.6,"voc_temp_coeff_pct_per_c":null,"connector":"Photovoltaic connectors, XT60i cable included","weight_lb":12.3,"source_type":"official product page","source_url":"https://us.ecoflow.com/products/nextgen-160w-portable-solar-panel","price_usd":369,"store_url":"https://us.ecoflow.com/products/nextgen-160w-portable-solar-panel","page":"https://ridgewatt.com/panels/ecoflow-160w-nextgen/"},{"id":"ecoflow-175w-rigid","brand":"EcoFlow","model":"175W Rigid Solar Panel","model_no":null,"type":"rigid","rated_w":175,"voc_v":25.5,"isc_a":8.3,"vmp_v":22.3,"imp_a":7.85,"voc_temp_coeff_pct_per_c":null,"connector":"Photovoltaic connectors (MC4 compatible)","weight_lb":20.5,"source_type":"official product page","source_url":"https://us.ecoflow.com/products/175w-rigid-solar-panel","price_usd":249,"store_url":"https://us.ecoflow.com/products/175w-rigid-solar-panel","page":"https://ridgewatt.com/panels/ecoflow-175w-rigid/"},{"id":"jackery-solarsaga-100-air","brand":"Jackery","model":"SolarSaga 100 Air","model_no":null,"type":"portable","rated_w":100,"voc_v":29.7,"isc_a":4.1,"vmp_v":25.4,"imp_a":3.95,"voc_temp_coeff_pct_per_c":null,"connector":"Solar connector (MC4 type)","weight_lb":null,"source_type":"official product page","source_url":"https://www.jackery.com/products/jackery-solarsaga-100-air","price_usd":249,"store_url":"https://www.jackery.com/products/jackery-solarsaga-100-air","page":"https://ridgewatt.com/panels/jackery-solarsaga-100-air/"},{"id":"jackery-solarsaga-100-prime","brand":"Jackery","model":"SolarSaga 100 Prime","model_no":null,"type":"portable","rated_w":100,"voc_v":22.7,"isc_a":5.53,"vmp_v":18.7,"imp_a":5.3,"voc_temp_coeff_pct_per_c":null,"connector":"Solar connector (MC4 type)","weight_lb":null,"source_type":"manual","source_url":"https://www.jackery.com/products/jackery-solarsaga-100-prime-solar-panel","price_usd":199,"store_url":"https://www.jackery.com/products/jackery-solarsaga-100-prime-solar-panel","page":"https://ridgewatt.com/panels/jackery-solarsaga-100-prime/"},{"id":"bluetti-pv120","brand":"BLUETTI","model":"PV120 Solar Panel","model_no":null,"type":"portable","rated_w":120,"voc_v":24.4,"isc_a":6.43,"vmp_v":19.6,"imp_a":6.1,"voc_temp_coeff_pct_per_c":null,"connector":"MC4","weight_lb":14.9,"source_type":"official product page","source_url":"https://www.bluettipower.com/products/bluetti-pv120s-solar-panel-120w","price_usd":209,"store_url":"https://www.bluettipower.com/products/bluetti-pv120s-solar-panel-120w","page":"https://ridgewatt.com/panels/bluetti-pv120/"},{"id":"bluetti-sp100l","brand":"BLUETTI","model":"SP100L Solar Panel","model_no":null,"type":"portable","rated_w":100,"voc_v":24.62,"isc_a":5.13,"vmp_v":20.52,"imp_a":4.88,"voc_temp_coeff_pct_per_c":null,"connector":"MC4","weight_lb":10.9,"source_type":"manual","source_url":"https://www.bluettipower.com/products/foldable-solar-panel-sp100l","price_usd":199,"store_url":"https://www.bluettipower.com/products/foldable-solar-panel-sp100l","page":"https://ridgewatt.com/panels/bluetti-sp100l/"},{"id":"bluetti-sp200l","brand":"BLUETTI","model":"SP200L Solar Panel","model_no":null,"type":"portable","rated_w":200,"voc_v":24.6,"isc_a":10.8,"vmp_v":null,"imp_a":null,"voc_temp_coeff_pct_per_c":null,"connector":"MC4","weight_lb":17.15,"source_type":"official product page","source_url":"https://www.bluettipower.com/products/bluetti-sp200l-solar-panel-200w","price_usd":349,"store_url":"https://www.bluettipower.com/products/bluetti-sp200l-solar-panel-200w","page":"https://ridgewatt.com/panels/bluetti-sp200l/"},{"id":"bluetti-pv100fx","brand":"BLUETTI","model":"PV100 FX Flexible Solar Panel","model_no":null,"type":"flexible","rated_w":100,"voc_v":41.4,"isc_a":3.05,"vmp_v":null,"imp_a":null,"voc_temp_coeff_pct_per_c":null,"connector":"MC4","weight_lb":4.85,"source_type":"official product page","source_url":"https://www.bluettipower.com/products/pv100fx-flexible-solar-panel","price_usd":null,"store_url":"https://www.bluettipower.com/products/pv100fx-flexible-solar-panel","page":"https://ridgewatt.com/panels/bluetti-pv100fx/"},{"id":"anker-solix-ps400","brand":"Anker SOLIX","model":"PS400 Bifacial","model_no":null,"type":"portable","rated_w":400,"voc_v":57.6,"isc_a":8.75,"vmp_v":48,"imp_a":8.33,"voc_temp_coeff_pct_per_c":null,"connector":"MC4","weight_lb":21.8,"source_type":"retailer listing","source_url":"https://solarpowersupply.eu/solar-panels/anker-solix-ps400-bifacial-portable-solar-panel","price_usd":699.99,"store_url":"https://www.ankersolix.com/products/ps400-bifacial-portable-solar-panel","page":"https://ridgewatt.com/panels/anker-solix-ps400/"},{"id":"renogy-eflex-200","brand":"Renogy","model":"E.Flex 200W Portable Solar Panel","model_no":null,"type":"portable","rated_w":200,"voc_v":23.4,"isc_a":10.5,"vmp_v":20.16,"imp_a":9.92,"voc_temp_coeff_pct_per_c":null,"connector":"Solar connector (MC4 type)","weight_lb":null,"source_type":"official product page","source_url":"https://www.renogy.com/products/renogy-e-flex-200w-portable-solar-panel","price_usd":219.99,"store_url":"https://www.renogy.com/products/renogy-e-flex-200w-portable-solar-panel","page":"https://ridgewatt.com/panels/renogy-eflex-200/"},{"id":"renogy-ntype-200","brand":"Renogy","model":"200W N-Type Solar Panel","model_no":null,"type":"rigid","rated_w":200,"voc_v":23,"isc_a":11.05,"vmp_v":19.2,"imp_a":10.42,"voc_temp_coeff_pct_per_c":null,"connector":"Solar connectors (MC4 type)","weight_lb":26.46,"source_type":"official product page","source_url":"https://www.renogy.com/products/renogy-n-type-solar-panel","price_usd":179.99,"store_url":"https://www.renogy.com/products/renogy-n-type-solar-panel","page":"https://ridgewatt.com/panels/renogy-ntype-200/"},{"id":"renogy-bifacial-250","brand":"Renogy","model":"250W N-Type Bifacial Solar Panel","model_no":null,"type":"rigid","rated_w":250,"voc_v":22.35,"isc_a":13.49,"vmp_v":19.52,"imp_a":12.81,"voc_temp_coeff_pct_per_c":null,"connector":"Solar connector (MC4 type)","weight_lb":27.3,"source_type":"official product page","source_url":"https://www.renogy.com/products/renogy-16bb-n-type-250-watt-bifacial-solar-panel","price_usd":264.99,"store_url":"https://www.renogy.com/products/renogy-16bb-n-type-250-watt-bifacial-solar-panel","page":"https://ridgewatt.com/panels/renogy-bifacial-250/"},{"id":"renogy-50w-rigid","brand":"Renogy","model":"50W Mono N-Type Rigid Solar Panel","model_no":null,"type":"rigid","rated_w":50,"voc_v":22.3,"isc_a":2.94,"vmp_v":18.6,"imp_a":2.69,"voc_temp_coeff_pct_per_c":null,"connector":"Solar connectors (MC4 type)","weight_lb":7.72,"source_type":"official product page","source_url":"https://www.renogy.com/products/50-watt-12-volt-monocrystalline-solar-panel","price_usd":55.99,"store_url":"https://www.renogy.com/products/50-watt-12-volt-monocrystalline-solar-panel","page":"https://ridgewatt.com/panels/renogy-50w-rigid/"},{"id":"renogy-100w-flexible","brand":"Renogy","model":"100W Lightweight Flexible Solar Panel","model_no":null,"type":"flexible","rated_w":100,"voc_v":22.5,"isc_a":5.75,"vmp_v":18.9,"imp_a":5.29,"voc_temp_coeff_pct_per_c":null,"connector":"Solar connector (MC4 type)","weight_lb":4.2,"source_type":"official product page","source_url":"https://www.renogy.com/products/100-watt-12-volt-flexible-monocrystalline-solar-panel","price_usd":149.99,"store_url":"https://www.renogy.com/products/100-watt-12-volt-flexible-monocrystalline-solar-panel","page":"https://ridgewatt.com/panels/renogy-100w-flexible/"},{"id":"renogy-200w-flexible","brand":"Renogy","model":"200W Flexible Solar Panel","model_no":null,"type":"flexible","rated_w":200,"voc_v":23.9,"isc_a":10.74,"vmp_v":20.1,"imp_a":10.02,"voc_temp_coeff_pct_per_c":null,"connector":"Solar connector (MC4 type)","weight_lb":10.8,"source_type":"official product page","source_url":"https://www.renogy.com/products/200-watt-12-volt-flexible-monocrystalline-solar-panel","price_usd":311.99,"store_url":"https://www.renogy.com/products/200-watt-12-volt-flexible-monocrystalline-solar-panel","page":"https://ridgewatt.com/panels/renogy-200w-flexible/"},{"id":"richsolar-mega-50","brand":"Rich Solar","model":"MEGA 50","model_no":null,"type":"rigid","rated_w":50,"voc_v":20.8,"isc_a":3.13,"vmp_v":17.6,"imp_a":2.84,"voc_temp_coeff_pct_per_c":null,"connector":"Solar connector (MC4 type)","weight_lb":8,"source_type":"official product page","source_url":"https://richsolar.com/products/mega-50-50-watt-12-volt-solar-panel","price_usd":69.99,"store_url":"https://richsolar.com/products/mega-50-50-watt-12-volt-solar-panel","page":"https://ridgewatt.com/panels/richsolar-mega-50/"},{"id":"richsolar-mega-100","brand":"Rich Solar","model":"MEGA 100","model_no":null,"type":"rigid","rated_w":100,"voc_v":22.8,"isc_a":5.78,"vmp_v":18.6,"imp_a":5.38,"voc_temp_coeff_pct_per_c":null,"connector":"Solar connector (MC4 type)","weight_lb":13.2,"source_type":"official product page","source_url":"https://richsolar.com/products/mega-100-100-watt-12-volt-solar-panel","price_usd":119.99,"store_url":"https://richsolar.com/products/mega-100-100-watt-12-volt-solar-panel","page":"https://ridgewatt.com/panels/richsolar-mega-100/"},{"id":"richsolar-mega-100-slim","brand":"Rich Solar","model":"MEGA 100 SLIM","model_no":null,"type":"rigid","rated_w":100,"voc_v":23.6,"isc_a":5.38,"vmp_v":19.6,"imp_a":5.1,"voc_temp_coeff_pct_per_c":null,"connector":"Solar connector (MC4 type)","weight_lb":12.4,"source_type":"official product page","source_url":"https://richsolar.com/products/mega-100-slim-100-watt-slim-solar-panel-2025","price_usd":129.99,"store_url":"https://richsolar.com/products/mega-100-slim-100-watt-slim-solar-panel-2025","page":"https://ridgewatt.com/panels/richsolar-mega-100-slim/"},{"id":"richsolar-mega-200","brand":"Rich Solar","model":"MEGA 200","model_no":null,"type":"rigid","rated_w":200,"voc_v":21.8,"isc_a":11.6,"vmp_v":18.4,"imp_a":10.9,"voc_temp_coeff_pct_per_c":null,"connector":"Solar connector (MC4 type)","weight_lb":24,"source_type":"official product page","source_url":"https://richsolar.com/products/mega-200-200-watt-12-volt-solar-panel","price_usd":239.99,"store_url":"https://richsolar.com/products/mega-200-200-watt-12-volt-solar-panel","page":"https://ridgewatt.com/panels/richsolar-mega-200/"},{"id":"richsolar-mega-200-pro","brand":"Rich Solar","model":"MEGA 200 PRO (24V)","model_no":null,"type":"rigid","rated_w":200,"voc_v":43.5,"isc_a":5.93,"vmp_v":36.3,"imp_a":5.51,"voc_temp_coeff_pct_per_c":null,"connector":"Solar connector (MC4 type)","weight_lb":24,"source_type":"official product page","source_url":"https://richsolar.com/products/mega-200-max-200-watt-24-volt-solar-panel","price_usd":249.99,"store_url":"https://richsolar.com/products/mega-200-max-200-watt-24-volt-solar-panel","page":"https://ridgewatt.com/panels/richsolar-mega-200-pro/"},{"id":"richsolar-mega-100-flex","brand":"Rich Solar","model":"MEGA 100 FLEX","model_no":null,"type":"flexible","rated_w":100,"voc_v":20.4,"isc_a":6.13,"vmp_v":17.1,"imp_a":5.85,"voc_temp_coeff_pct_per_c":null,"connector":"Solar connector (MC4 type)","weight_lb":4.8,"source_type":"official product page","source_url":"https://richsolar.com/products/mega-100-flex-100w-12v-flexible-solar-panel","price_usd":169.99,"store_url":"https://richsolar.com/products/mega-100-flex-100w-12v-flexible-solar-panel","page":"https://ridgewatt.com/panels/richsolar-mega-100-flex/"},{"id":"richsolar-mega-200-pro-flex","brand":"Rich Solar","model":"MEGA 200 PRO FLEX (24V)","model_no":null,"type":"flexible","rated_w":200,"voc_v":40.8,"isc_a":6.23,"vmp_v":34.2,"imp_a":5.85,"voc_temp_coeff_pct_per_c":null,"connector":"Solar connector (MC4 type)","weight_lb":8.6,"source_type":"official product page","source_url":"https://richsolar.com/products/mega-200-flex-pro-200w-24v-flexible-solar-panel","price_usd":299.99,"store_url":"https://richsolar.com/products/mega-200-flex-pro-200w-24v-flexible-solar-panel","page":"https://ridgewatt.com/panels/richsolar-mega-200-pro-flex/"}],"compatibility":[{"station_id":"ecoflow-river-3-plus","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":220,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":220,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 55V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-3-plus","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 55V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-3-plus","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":220,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-3-plus","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":700,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":400,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-delta-3-plus","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":240,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":800,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-delta-3-plus","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-plus","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60i + 1 panel on XT60i","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on XT60 (High-PV) + 1 panel on XT60i (Low-PV)","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":700,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"anker-solix-ps200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60 (High-PV)","two_panels_w":399,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60 (High-PV) + 1 panel on XT60i (Low-PV)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"anker-solix-ps400","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60 (High-PV) + 1 panel on XT60i (Low-PV)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (High-PV)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-3","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60 (High-PV) + 1 panel on XT60i (Low-PV)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300-plus","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":90,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":90,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 27V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300-plus","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":92,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":92,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 27V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300-plus","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 27V limit. Cold makes panels push more voltage."},{"station_id":"jackery-explorer-300-plus","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 27V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300-plus","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":86,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":86,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":86,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":86,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":92,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":92,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":93,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":93,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"ecoflow-175w-rigid","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (25.5V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 27.9V, above the 27V limit. Cold makes panels push more voltage."},{"station_id":"jackery-explorer-300-plus","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 27V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300-plus","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":94,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":94,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":98,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":98,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 27V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300-plus","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 27V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300-plus","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":96,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":96,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":98,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":98,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":93,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":95,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":95,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":88,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":93,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":93,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":98,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":98,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":92,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":92,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 27V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300-plus","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":86,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":86,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-300-plus","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 27V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-1000-v2","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":189,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":378,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 10.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-1000-v2","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":193,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":386,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 10.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-1000-v2","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":290,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 10.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-1000-v2","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"On a 20°F (-7°C) morning the open-circuit voltage can reach about 63.1V, above 60V."},{"station_id":"jackery-explorer-1000-v2","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":240,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"bluetti-sp200l","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed."},{"station_id":"jackery-explorer-1000-v2","panel_id":"bluetti-pv100fx","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed."},{"station_id":"jackery-explorer-1000-v2","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"On a 20°F (-7°C) morning the open-circuit voltage can reach about 63.1V, above 60V."},{"station_id":"jackery-explorer-1000-v2","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":205,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 10.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-1000-v2","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":193,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":386,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 10.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-1000-v2","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-v2","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":331,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":662,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 12A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-2000-plus","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"On a 20°F (-7°C) morning the open-circuit voltage can reach about 63.1V, above 60V."},{"station_id":"jackery-explorer-2000-plus","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":240,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"bluetti-sp200l","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed."},{"station_id":"jackery-explorer-2000-plus","panel_id":"bluetti-pv100fx","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed."},{"station_id":"jackery-explorer-2000-plus","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":800,"cold_f":20,"reason":"On a 20°F (-7°C) morning the open-circuit voltage can reach about 63.1V, above 60V."},{"station_id":"jackery-explorer-2000-plus","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":234,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":468,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 12A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-2000-plus","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-plus","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":180,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":360,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac70","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60 (XT60PM-M)","two_panels_w":410,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":368,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac70","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":276,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60 (XT60PM-M)","two_panels_w":276,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac70","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60 (XT60PM-M)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on XT60 (XT60PM-M)","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 58V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-ac70","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60 (XT60PM-M)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60 (XT60PM-M)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60 (XT60PM-M)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60 (XT60PM-M)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on XT60 (XT60PM-M)","two_panels_w":480,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 58V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-ac70","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":192,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":384,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac70","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":195,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":390,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac70","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60 (XT60PM-M)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":400,"cold_f":20,"reason":"The panels can push 10A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac70","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60 (XT60PM-M)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":368,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac70","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60 (XT60PM-M)","two_panels_w":363,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60 (XT60PM-M)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60 (XT60PM-M)","two_panels_w":342,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":180,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":360,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC7909","two_panels_w":410,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":368,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":276,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC7909","two_panels_w":276,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC7909","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on DC7909","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-ac180","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC7909","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC7909","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC7909","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC7909","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on DC7909","two_panels_w":480,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-ac180","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":192,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":384,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":195,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":390,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC7909","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":400,"cold_f":20,"reason":"The panels can push 10A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC7909","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":368,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC7909","two_panels_w":363,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC7909","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC7909","two_panels_w":342,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input (via DC input cable + solar charging cable)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input (via DC input cable + solar charging cable)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input (via DC input cable + solar charging cable)","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input (via DC input cable + solar charging cable)","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input (via DC input cable + solar charging cable)","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input (via DC input cable + solar charging cable)","two_panels_w":700,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"anker-solix-ps200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":399,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input (via DC input cable + solar charging cable)","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input (via DC input cable + solar charging cable)","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"anker-solix-ps400","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input (via DC input cable + solar charging cable)","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input (via DC input cable + solar charging cable)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input (via DC input cable + solar charging cable)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input (via DC input cable + solar charging cable)","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input (via DC input cable + solar charging cable)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input (via DC input cable + solar charging cable)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200l","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input (via DC input cable + solar charging cable)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000-gen2","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":595,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":438,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":396,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"anker-solix-c1000-gen2","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":320,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":350,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":239,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":600,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"anker-solix-c1000-gen2","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":500,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000-gen2","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"ecoflow-river-2","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-2","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":"The panels can push 10A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-2","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-2","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-2","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":"The panels can push 9.7A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-2","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-2","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-2","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":"The panels can push 8.6A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-2","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2","panel_id":"jackery-solarsaga-100-air","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":"Fine in mild weather (29.7V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 32.5V, above the 30V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-2","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-2","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-2","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":"The panels can push 9.9A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-2","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-2","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-2","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":"The panels can push 10A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-2","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-2","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-2","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-2-max","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"ecoflow-400w-portable","one_panel":"Works, with a catch","one_panel_w":220,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":"Fine in mild weather (48V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 52.6V, above the 50V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-2-max","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":220,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 50V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-2-max","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 50V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-2-max","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":220,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"ecoflow-400w-portable","one_panel":"Works, with a catch","one_panel_w":220,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":"Fine in mild weather (48V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 52.6V, above the 50V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-2-max-500","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":220,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 50V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-2-max-500","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 50V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-2-max-500","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":220,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-max-500","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"ecoflow-400w-portable","one_panel":"Works, with a catch","one_panel_w":220,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":"Fine in mild weather (48V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 52.6V, above the 50V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-2-pro","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":220,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 50V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-2-pro","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 50V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-2-pro","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":220,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-2-pro","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-trail-300-dc","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-trail-300-dc","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-trail-300-dc","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-trail-300-dc","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-trail-300-dc","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"jackery-solarsaga-100-air","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":"Fine in mild weather (29.7V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 32.5V, above the 30V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-trail-300-dc","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-trail-300-dc","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-trail-300-dc","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-trail-300-dc","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-trail-300-dc","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":"The panels can push 10A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-trail-300-dc","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-trail-300-dc","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-trail-300-dc","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":110,"cold_f":20,"reason":""},{"station_id":"ecoflow-trail-300-dc","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-delta-3-classic","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":414,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-delta-3-classic","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":500,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-delta-3-classic","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-classic","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":414,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-delta-3","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":500,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-delta-3","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":359,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-delta-3-max","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":500,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-delta-3-max","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar/Car input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":700,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":240,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":800,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-max-plus","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":738,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60i)","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60i)","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":497,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-delta-3-ultra","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":800,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-delta-3-ultra","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60i)","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":700,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":240,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":800,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-3-ultra-plus","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input 1 (XT60i) + 1 panel on Solar input 2 (XT60i)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":700,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-delta-2-max","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":240,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":800,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-delta-2-max","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-2-max","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":700,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"anker-solix-ps200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":399,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"anker-solix-ps400","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":400,"cold_f":20,"reason":"Open-circuit voltage 22V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":400,"cold_f":20,"reason":"Open-circuit voltage 24.8V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in series on High-PV","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":438,"cold_f":20,"reason":"Open-circuit voltage 21.5V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"bluetti-pv200d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":396,"cold_f":20,"reason":"Open-circuit voltage 24.6V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"bluetti-pv350d","one_panel":"Works, with a catch","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":700,"cold_f":20,"reason":"Working voltage 27.6V is below the 30V minimum, so charging may drop out in weak light."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"anker-solix-ps100","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 25.9V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"anker-solix-ps200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on High-PV","two_panels_w":399,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"ecoflow-100w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 20.3V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"ecoflow-100w-flexible","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 20.3V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"ecoflow-110w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":220,"cold_f":20,"reason":"Open-circuit voltage 21.8V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"ecoflow-160w-nextgen","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":320,"cold_f":20,"reason":"Open-circuit voltage 21.3V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"ecoflow-175w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":350,"cold_f":20,"reason":"Open-circuit voltage 25.5V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 29.7V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"jackery-solarsaga-100-prime","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":198,"cold_f":20,"reason":"Open-circuit voltage 22.7V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"bluetti-pv120","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":239,"cold_f":20,"reason":"Open-circuit voltage 24.4V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"bluetti-sp100l","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 24.6V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"bluetti-sp200l","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":400,"cold_f":20,"reason":"Open-circuit voltage 24.6V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on High-PV","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"anker-solix-ps400","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in series on High-PV","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"renogy-eflex-200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":400,"cold_f":20,"reason":"Open-circuit voltage 23.4V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"renogy-ntype-200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":400,"cold_f":20,"reason":"Open-circuit voltage 23V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"renogy-bifacial-250","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":500,"cold_f":20,"reason":"Open-circuit voltage 22.4V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"renogy-50w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":100,"cold_f":20,"reason":"Open-circuit voltage 22.3V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"renogy-100w-flexible","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 22.5V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"renogy-200w-flexible","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":400,"cold_f":20,"reason":"Open-circuit voltage 23.9V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"richsolar-mega-50","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":100,"cold_f":20,"reason":"Open-circuit voltage 20.8V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"richsolar-mega-100","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 22.8V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"richsolar-mega-100-slim","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 23.6V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"richsolar-mega-200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":400,"cold_f":20,"reason":"Open-circuit voltage 21.8V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Low-PV","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"richsolar-mega-100-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 20.4V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Low-PV","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.8V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on High-PV","two_panels_w":800,"cold_f":20,"reason":"Open-circuit voltage 48V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 21.5V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"bluetti-pv200d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.6V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"anker-solix-ps100","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 25.9V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on High-PV","two_panels_w":399,"cold_f":20,"reason":"Open-circuit voltage 57.6V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"ecoflow-100w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 20.3V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"ecoflow-100w-flexible","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 20.3V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"ecoflow-110w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 21.8V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"ecoflow-160w-nextgen","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 21.3V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"ecoflow-175w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 25.5V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"jackery-solarsaga-100-prime","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.7V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"bluetti-pv120","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.4V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"bluetti-sp100l","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.6V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"bluetti-sp200l","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.6V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on High-PV","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 41.4V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on High-PV","two_panels_w":800,"cold_f":20,"reason":"Open-circuit voltage 57.6V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"renogy-eflex-200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 23.4V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"renogy-ntype-200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 23V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"renogy-bifacial-250","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.4V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"renogy-50w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.3V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"renogy-100w-flexible","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.5V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"renogy-200w-flexible","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 23.9V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"richsolar-mega-50","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 20.8V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"richsolar-mega-100","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.8V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"richsolar-mega-100-slim","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 23.6V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"richsolar-mega-200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 21.8V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in series on High-PV","two_panels_w":400,"cold_f":20,"reason":"Open-circuit voltage 43.5V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"richsolar-mega-100-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High-PV + 1 panel on High-PV","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 20.4V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-pro-ultra-x","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in series on High-PV","two_panels_w":400,"cold_f":20,"reason":"Open-circuit voltage 40.8V is below the 80V minimum for this input, so it will not start charging."},{"station_id":"ecoflow-delta-mini","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":180,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":300,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-mini","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":300,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":300,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":300,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":300,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-mini","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":300,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":276,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":300,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-mini","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"anker-solix-ps200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":300,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":300,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":300,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":300,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"anker-solix-ps400","one_panel":"Works","one_panel_w":300,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":300,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":300,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":192,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":300,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-mini","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":195,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":300,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-mini","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":300,"cold_f":20,"reason":"The panels can push 10A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-mini","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":300,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-mini","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":300,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-mini","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":300,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":180,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":360,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-1300","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":368,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-1300","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":276,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":276,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-1300","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"anker-solix-ps200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":399,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"anker-solix-ps400","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":192,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":384,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-1300","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":195,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":390,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-1300","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"The panels can push 10A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-1300","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":368,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-1300","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":363,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1300","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":342,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":180,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":360,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-1000","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":368,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-1000","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":276,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":276,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-1000","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"anker-solix-ps200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":399,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"anker-solix-ps400","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":192,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":384,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-1000","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":195,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":390,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-1000","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"The panels can push 10A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-1000","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":368,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-delta-1000","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":363,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-delta-1000","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":342,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.8V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.9V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-max","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max","panel_id":"bluetti-pv200d","one_panel":"Works, with a catch","one_panel_w":198,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.9V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-max","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max","panel_id":"anker-solix-ps100","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 25.9V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max","panel_id":"ecoflow-175w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 25.5V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max","panel_id":"bluetti-pv120","one_panel":"Works, with a catch","one_panel_w":120,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.4V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.7V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-max","panel_id":"bluetti-sp100l","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 27V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-max","panel_id":"bluetti-sp200l","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.9V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-max","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max","panel_id":"renogy-eflex-200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (23.4V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 25.6V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-max","panel_id":"renogy-ntype-200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (23V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 25.2V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-max","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 12A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-max","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max","panel_id":"renogy-200w-flexible","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (23.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.2V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-max","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max","panel_id":"richsolar-mega-100-slim","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (23.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 25.8V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-max","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max-plus","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max-plus","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.8V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.9V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-max-plus","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max-plus","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max-plus","panel_id":"bluetti-pv200d","one_panel":"Works, with a catch","one_panel_w":198,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.9V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-max-plus","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max-plus","panel_id":"anker-solix-ps100","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 25.9V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max-plus","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max-plus","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max-plus","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max-plus","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max-plus","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max-plus","panel_id":"ecoflow-175w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 25.5V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max-plus","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max-plus","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max-plus","panel_id":"bluetti-pv120","one_panel":"Works, with a catch","one_panel_w":120,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.4V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.7V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-max-plus","panel_id":"bluetti-sp100l","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 27V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-max-plus","panel_id":"bluetti-sp200l","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.9V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-max-plus","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max-plus","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max-plus","panel_id":"renogy-eflex-200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (23.4V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 25.6V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-max-plus","panel_id":"renogy-ntype-200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (23V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 25.2V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-max-plus","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 12A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-max-plus","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max-plus","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max-plus","panel_id":"renogy-200w-flexible","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (23.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.2V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-max-plus","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max-plus","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max-plus","panel_id":"richsolar-mega-100-slim","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (23.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 25.8V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-max-plus","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max-plus","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-max-plus","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-max-plus","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-mini","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-mini","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 10A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-mini","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 39V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-mini","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-mini","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 9.7A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-mini","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-mini","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-mini","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 39V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-mini","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-mini","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-mini","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-mini","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 8.6A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-mini","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-mini","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-mini","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-mini","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-mini","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-mini","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-mini","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 39V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-mini","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 39V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-mini","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 9.9A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-mini","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-mini","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-mini","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-mini","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-mini","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 10A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-mini","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-mini","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-mini","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-mini","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-mini","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 39V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-mini","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-mini","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 39V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-plus","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-plus","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.8V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.9V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-plus","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-plus","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-plus","panel_id":"bluetti-pv200d","one_panel":"Works, with a catch","one_panel_w":198,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.9V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-plus","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-plus","panel_id":"anker-solix-ps100","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 25.9V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-plus","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-plus","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-plus","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-plus","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-plus","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-plus","panel_id":"ecoflow-175w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 25.5V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-plus","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-plus","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-plus","panel_id":"bluetti-pv120","one_panel":"Works, with a catch","one_panel_w":120,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.4V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.7V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-plus","panel_id":"bluetti-sp100l","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 27V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-plus","panel_id":"bluetti-sp200l","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.9V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-plus","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-plus","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-plus","panel_id":"renogy-eflex-200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (23.4V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 25.6V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-plus","panel_id":"renogy-ntype-200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (23V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 25.2V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-plus","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 12A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river-plus","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-plus","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-plus","panel_id":"renogy-200w-flexible","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (23.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.2V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-plus","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-plus","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-plus","panel_id":"richsolar-mega-100-slim","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (23.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 25.8V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river-plus","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-plus","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river-plus","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river-plus","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.8V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.9V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river","panel_id":"bluetti-pv200d","one_panel":"Works, with a catch","one_panel_w":198,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.9V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river","panel_id":"anker-solix-ps100","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 25.9V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river","panel_id":"ecoflow-175w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 25.5V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"ecoflow-river","panel_id":"bluetti-pv120","one_panel":"Works, with a catch","one_panel_w":120,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.4V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.7V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river","panel_id":"bluetti-sp100l","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 27V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river","panel_id":"bluetti-sp200l","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (24.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.9V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river","panel_id":"renogy-eflex-200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (23.4V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 25.6V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river","panel_id":"renogy-ntype-200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (23V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 25.2V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 12A, so the station caps it. Safe, you just lose some watts."},{"station_id":"ecoflow-river","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river","panel_id":"renogy-200w-flexible","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (23.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.2V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"ecoflow-river","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river","panel_id":"richsolar-mega-100-slim","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (23.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 25.8V, above the 25V limit. Cold makes panels push more voltage."},{"station_id":"ecoflow-river","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"ecoflow-river","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"ecoflow-river","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 25V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-eb3a","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":153,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":153,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb3a","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":170,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":170,"cold_f":20,"reason":"The panels can push 10A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb3a","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-eb3a","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":156,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":156,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb3a","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":173,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":173,"cold_f":20,"reason":"The panels can push 9.7A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb3a","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-eb3a","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":184,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-eb3a","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-eb3a","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":145,"cold_f":20,"reason":""},{"station_id":"bluetti-eb3a","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":145,"cold_f":20,"reason":""},{"station_id":"bluetti-eb3a","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":156,"cold_f":20,"reason":""},{"station_id":"bluetti-eb3a","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":158,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":158,"cold_f":20,"reason":"The panels can push 8.6A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb3a","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":190,"cold_f":20,"reason":""},{"station_id":"bluetti-eb3a","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-eb3a","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":159,"cold_f":20,"reason":""},{"station_id":"bluetti-eb3a","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":167,"cold_f":20,"reason":""},{"station_id":"bluetti-eb3a","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":174,"cold_f":20,"reason":""},{"station_id":"bluetti-eb3a","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-eb3a","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-eb3a","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-eb3a","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":171,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":171,"cold_f":20,"reason":"The panels can push 9.9A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb3a","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":163,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":163,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb3a","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":166,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":166,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb3a","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-eb3a","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":161,"cold_f":20,"reason":""},{"station_id":"bluetti-eb3a","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":171,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":171,"cold_f":20,"reason":"The panels can push 10A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb3a","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-eb3a","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":158,"cold_f":20,"reason":""},{"station_id":"bluetti-eb3a","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":167,"cold_f":20,"reason":""},{"station_id":"bluetti-eb3a","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":156,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":156,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb3a","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-eb3a","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":145,"cold_f":20,"reason":""},{"station_id":"bluetti-eb3a","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac2a","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":148,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":148,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac2a","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":164,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":164,"cold_f":20,"reason":"The panels can push 10A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac2a","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac2a","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":151,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":151,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac2a","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":167,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":167,"cold_f":20,"reason":"The panels can push 9.7A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac2a","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac2a","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":177,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-ac2a","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac2a","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":140,"cold_f":20,"reason":""},{"station_id":"bluetti-ac2a","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":140,"cold_f":20,"reason":""},{"station_id":"bluetti-ac2a","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":151,"cold_f":20,"reason":""},{"station_id":"bluetti-ac2a","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":153,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":153,"cold_f":20,"reason":"The panels can push 8.6A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac2a","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":183,"cold_f":20,"reason":""},{"station_id":"bluetti-ac2a","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac2a","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":153,"cold_f":20,"reason":""},{"station_id":"bluetti-ac2a","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":161,"cold_f":20,"reason":""},{"station_id":"bluetti-ac2a","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":168,"cold_f":20,"reason":""},{"station_id":"bluetti-ac2a","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac2a","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac2a","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac2a","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":165,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":165,"cold_f":20,"reason":"The panels can push 9.9A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac2a","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":157,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":157,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac2a","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":160,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac2a","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac2a","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":155,"cold_f":20,"reason":""},{"station_id":"bluetti-ac2a","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":165,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":165,"cold_f":20,"reason":"The panels can push 10A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac2a","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac2a","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":153,"cold_f":20,"reason":""},{"station_id":"bluetti-ac2a","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":161,"cold_f":20,"reason":""},{"station_id":"bluetti-ac2a","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":151,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":151,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac2a","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac2a","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":140,"cold_f":20,"reason":""},{"station_id":"bluetti-ac2a","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac60","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":144,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":144,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac60","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":160,"cold_f":20,"reason":"The panels can push 10A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac60","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac60","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":147,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":147,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac60","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":163,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":163,"cold_f":20,"reason":"The panels can push 9.7A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac60","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac60","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":173,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-ac60","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac60","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":137,"cold_f":20,"reason":""},{"station_id":"bluetti-ac60","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":137,"cold_f":20,"reason":""},{"station_id":"bluetti-ac60","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":147,"cold_f":20,"reason":""},{"station_id":"bluetti-ac60","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":149,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":149,"cold_f":20,"reason":"The panels can push 8.6A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac60","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":178,"cold_f":20,"reason":""},{"station_id":"bluetti-ac60","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac60","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":150,"cold_f":20,"reason":""},{"station_id":"bluetti-ac60","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":157,"cold_f":20,"reason":""},{"station_id":"bluetti-ac60","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":164,"cold_f":20,"reason":""},{"station_id":"bluetti-ac60","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac60","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac60","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac60","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":161,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":161,"cold_f":20,"reason":"The panels can push 9.9A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac60","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":154,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":154,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac60","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":156,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":156,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac60","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac60","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":151,"cold_f":20,"reason":""},{"station_id":"bluetti-ac60","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":161,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":161,"cold_f":20,"reason":"The panels can push 10A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac60","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac60","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":149,"cold_f":20,"reason":""},{"station_id":"bluetti-ac60","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":157,"cold_f":20,"reason":""},{"station_id":"bluetti-ac60","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":147,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":147,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac60","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac60","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":137,"cold_f":20,"reason":""},{"station_id":"bluetti-ac60","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac180t","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":180,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":360,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180t","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60)","two_panels_w":410,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":368,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180t","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":276,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60)","two_panels_w":276,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180t","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input (XT60)","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-ac180t","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input (XT60)","two_panels_w":480,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-ac180t","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":192,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":384,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180t","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":195,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":390,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180t","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":400,"cold_f":20,"reason":"The panels can push 10A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180t","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":368,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180t","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60)","two_panels_w":363,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input (XT60)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180t","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input (XT60)","two_panels_w":342,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":580,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-ac240","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":800,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-ac240","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac240","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":700,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-apex-300","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":240,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":800,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-apex-300","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-apex-300","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":180,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":360,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180p","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":410,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":368,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180p","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":276,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":276,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180p","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-ac180p","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":480,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-ac180p","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":192,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":384,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180p","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":195,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":390,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180p","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"The panels can push 10A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180p","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":368,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac180p","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":363,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac180p","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":342,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":700,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"anker-solix-ps200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":399,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"anker-solix-ps400","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200max","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":700,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"anker-solix-ps200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":399,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"anker-solix-ps400","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p-l","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"Open-circuit voltage 22V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"Open-circuit voltage 24.8V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":700,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":438,"cold_f":20,"reason":"Open-circuit voltage 21.5V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"bluetti-pv200d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":396,"cold_f":20,"reason":"Open-circuit voltage 24.6V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":662,"cold_f":20,"reason":"Open-circuit voltage 33V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"anker-solix-ps100","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 25.9V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"anker-solix-ps200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":399,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p","panel_id":"ecoflow-100w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 20.3V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"ecoflow-100w-flexible","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 20.3V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"ecoflow-110w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":220,"cold_f":20,"reason":"Open-circuit voltage 21.8V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"ecoflow-160w-nextgen","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":320,"cold_f":20,"reason":"Open-circuit voltage 21.3V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"ecoflow-175w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":350,"cold_f":20,"reason":"Open-circuit voltage 25.5V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 29.7V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"jackery-solarsaga-100-prime","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":198,"cold_f":20,"reason":"Open-circuit voltage 22.7V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"bluetti-pv120","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":239,"cold_f":20,"reason":"Open-circuit voltage 24.4V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"bluetti-sp100l","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 24.6V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"bluetti-sp200l","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"Open-circuit voltage 24.6V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p","panel_id":"anker-solix-ps400","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":700,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p","panel_id":"renogy-eflex-200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"Open-circuit voltage 23.4V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"renogy-ntype-200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"Open-circuit voltage 23V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"renogy-bifacial-250","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":468,"cold_f":20,"reason":"Open-circuit voltage 22.4V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"renogy-50w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":100,"cold_f":20,"reason":"Open-circuit voltage 22.3V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"renogy-100w-flexible","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 22.5V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"renogy-200w-flexible","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"Open-circuit voltage 23.9V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"richsolar-mega-50","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":100,"cold_f":20,"reason":"Open-circuit voltage 20.8V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"richsolar-mega-100","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 22.8V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"richsolar-mega-100-slim","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 23.6V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"richsolar-mega-200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"Open-circuit voltage 21.8V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac200p","panel_id":"richsolar-mega-100-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 20.4V is below the 35V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ac200p","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"Working voltage 34.2V is below the 35V minimum, so charging may drop out in weak light."},{"station_id":"bluetti-ac50b","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":153,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":153,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50b","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":170,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":170,"cold_f":20,"reason":"The panels can push 10A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50b","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac50b","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":156,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":156,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50b","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":173,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":173,"cold_f":20,"reason":"The panels can push 9.7A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50b","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac50b","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":184,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-ac50b","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac50b","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":145,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50b","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":145,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50b","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":156,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50b","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":158,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":158,"cold_f":20,"reason":"The panels can push 8.6A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50b","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":190,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50b","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac50b","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":159,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50b","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":167,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50b","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":174,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50b","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50b","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac50b","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac50b","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":171,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":171,"cold_f":20,"reason":"The panels can push 9.9A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50b","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":163,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":163,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50b","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":166,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":166,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50b","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50b","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":161,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50b","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":171,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":171,"cold_f":20,"reason":"The panels can push 10A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50b","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50b","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":158,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50b","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":167,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50b","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":156,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":156,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50b","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac50b","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":145,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50b","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac50p","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":153,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":153,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50p","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":170,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":170,"cold_f":20,"reason":"The panels can push 10A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50p","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac50p","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":156,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":156,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50p","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":173,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":173,"cold_f":20,"reason":"The panels can push 9.7A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50p","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac50p","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":184,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-ac50p","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac50p","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":145,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50p","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":145,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50p","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":156,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50p","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":158,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":158,"cold_f":20,"reason":"The panels can push 8.6A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50p","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":190,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50p","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac50p","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":159,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50p","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":167,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50p","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":174,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50p","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50p","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac50p","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac50p","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":171,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":171,"cold_f":20,"reason":"The panels can push 9.9A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50p","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":163,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":163,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50p","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":166,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":166,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50p","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50p","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":161,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50p","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":171,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":171,"cold_f":20,"reason":"The panels can push 10A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50p","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50p","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":158,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50p","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":167,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50p","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":156,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":156,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 8.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac50p","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac50p","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":145,"cold_f":20,"reason":""},{"station_id":"bluetti-ac50p","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ac70p","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":180,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":360,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac70p","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":410,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":368,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac70p","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":276,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":276,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac70p","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 58V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-ac70p","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":480,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 58V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-ac70p","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":192,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":384,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac70p","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":195,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":390,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac70p","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"The panels can push 10A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac70p","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":368,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ac70p","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":363,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ac70p","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":342,"cold_f":20,"reason":""},{"station_id":"bluetti-eb70s","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":144,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":144,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb70s","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":160,"cold_f":20,"reason":"The panels can push 10A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb70s","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-eb70s","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":147,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":147,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb70s","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":163,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":163,"cold_f":20,"reason":"The panels can push 9.7A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb70s","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-eb70s","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":173,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-eb70s","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-eb70s","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":137,"cold_f":20,"reason":""},{"station_id":"bluetti-eb70s","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":137,"cold_f":20,"reason":""},{"station_id":"bluetti-eb70s","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":147,"cold_f":20,"reason":""},{"station_id":"bluetti-eb70s","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":149,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":149,"cold_f":20,"reason":"The panels can push 8.6A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb70s","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":178,"cold_f":20,"reason":""},{"station_id":"bluetti-eb70s","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-eb70s","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":150,"cold_f":20,"reason":""},{"station_id":"bluetti-eb70s","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":157,"cold_f":20,"reason":""},{"station_id":"bluetti-eb70s","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":164,"cold_f":20,"reason":""},{"station_id":"bluetti-eb70s","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-eb70s","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-eb70s","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-eb70s","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":161,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":161,"cold_f":20,"reason":"The panels can push 9.9A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb70s","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":154,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":154,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb70s","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":156,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":156,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb70s","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-eb70s","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":151,"cold_f":20,"reason":""},{"station_id":"bluetti-eb70s","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":161,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":161,"cold_f":20,"reason":"The panels can push 10A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb70s","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-eb70s","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":149,"cold_f":20,"reason":""},{"station_id":"bluetti-eb70s","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":157,"cold_f":20,"reason":""},{"station_id":"bluetti-eb70s","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":147,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":147,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 8A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-eb70s","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-eb70s","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":137,"cold_f":20,"reason":""},{"station_id":"bluetti-eb70s","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ep500","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.8V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on PV input","two_panels_w":800,"cold_f":20,"reason":"Open-circuit voltage 48V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 21.5V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"bluetti-pv200d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.6V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on PV input","two_panels_w":700,"cold_f":20,"reason":"Open-circuit voltage 33V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"anker-solix-ps100","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 25.9V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on PV input","two_panels_w":399,"cold_f":20,"reason":"Working voltage 48V is below the 55V minimum, so charging may drop out in weak light."},{"station_id":"bluetti-ep500","panel_id":"ecoflow-100w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 20.3V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"ecoflow-100w-flexible","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 20.3V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"ecoflow-110w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 21.8V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"ecoflow-160w-nextgen","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 21.3V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"ecoflow-175w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 25.5V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in series on PV input","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 29.7V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"jackery-solarsaga-100-prime","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.7V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"bluetti-pv120","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.4V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"bluetti-sp100l","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.6V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"bluetti-sp200l","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.6V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on PV input","two_panels_w":200,"cold_f":20,"reason":"Open-circuit voltage 41.4V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in series on PV input","two_panels_w":800,"cold_f":20,"reason":"Working voltage 48V is below the 55V minimum, so charging may drop out in weak light."},{"station_id":"bluetti-ep500","panel_id":"renogy-eflex-200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 23.4V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"renogy-ntype-200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 23V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"renogy-bifacial-250","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.4V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"renogy-50w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.3V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"renogy-100w-flexible","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.5V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"renogy-200w-flexible","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 23.9V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"richsolar-mega-50","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 20.8V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"richsolar-mega-100","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.8V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"richsolar-mega-100-slim","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 23.6V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"richsolar-mega-200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 21.8V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on PV input","two_panels_w":400,"cold_f":20,"reason":"Open-circuit voltage 43.5V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"richsolar-mega-100-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 20.4V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Works","two_panels_wiring":"2 panels in series on PV input","two_panels_w":400,"cold_f":20,"reason":"Open-circuit voltage 40.8V is below the 55V minimum for this input, so it will not start charging."},{"station_id":"bluetti-ep500pro","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":331,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":662,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 12A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ep500pro","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"anker-solix-ps200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":240,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"anker-solix-ps400","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":234,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":468,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 12A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-ep500pro","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-ep500pro","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on PV input + 1 panel on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-10-mini","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-10-mini","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 10A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-10-mini","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-elite-10-mini","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-10-mini","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 9.7A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-10-mini","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-elite-10-mini","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-elite-10-mini","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-elite-10-mini","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-10-mini","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-10-mini","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-10-mini","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 8.6A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-10-mini","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-10-mini","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-elite-10-mini","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-10-mini","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-10-mini","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-10-mini","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-10-mini","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-elite-10-mini","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-elite-10-mini","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 9.9A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-10-mini","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-10-mini","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-10-mini","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-10-mini","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-10-mini","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 10A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-10-mini","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-10-mini","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-10-mini","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-10-mini","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-10-mini","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-elite-10-mini","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-10-mini","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-elite-30-v2","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":180,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":180,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-30-v2","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-30-v2","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-elite-30-v2","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":184,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-30-v2","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-30-v2","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-elite-30-v2","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-elite-30-v2","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-elite-30-v2","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":171,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-30-v2","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":171,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-30-v2","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":184,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-30-v2","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":186,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-30-v2","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-30-v2","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-elite-30-v2","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":187,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-30-v2","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":196,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-30-v2","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-30-v2","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-30-v2","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-elite-30-v2","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-elite-30-v2","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-30-v2","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":192,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":192,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-30-v2","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":195,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":195,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-30-v2","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-30-v2","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":189,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-30-v2","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The panels can push 10A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-30-v2","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-30-v2","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":186,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-30-v2","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":196,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-30-v2","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":184,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-30-v2","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-elite-30-v2","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":171,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-30-v2","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-elite-100-v2","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":552,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-elite-100-v2","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":800,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-elite-100-v2","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-v2","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":180,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":350,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-100-mini","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":350,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-100-mini","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":276,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":276,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-100-mini","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":350,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-elite-100-mini","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":350,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":350,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-elite-100-mini","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":192,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":350,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-100-mini","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":195,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":350,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-100-mini","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":350,"cold_f":20,"reason":"The panels can push 10A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-100-mini","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":350,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-elite-100-mini","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-100-mini","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":342,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":552,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-elite-200-v2","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":800,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-elite-200-v2","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-200-v2","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":607,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-elite-300","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":800,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-elite-300","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-300","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":552,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-elite-400","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":800,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-elite-400","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-elite-400","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-handsfree-1","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":148,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":148,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-handsfree-1","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":164,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":164,"cold_f":20,"reason":"The panels can push 10A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-handsfree-1","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-handsfree-1","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":151,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":151,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-handsfree-1","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":167,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":167,"cold_f":20,"reason":"The panels can push 9.7A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-handsfree-1","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-handsfree-1","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":177,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-handsfree-1","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-handsfree-1","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":140,"cold_f":20,"reason":""},{"station_id":"bluetti-handsfree-1","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":140,"cold_f":20,"reason":""},{"station_id":"bluetti-handsfree-1","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":151,"cold_f":20,"reason":""},{"station_id":"bluetti-handsfree-1","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":153,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":153,"cold_f":20,"reason":"The panels can push 8.6A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-handsfree-1","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":183,"cold_f":20,"reason":""},{"station_id":"bluetti-handsfree-1","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-handsfree-1","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":153,"cold_f":20,"reason":""},{"station_id":"bluetti-handsfree-1","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":161,"cold_f":20,"reason":""},{"station_id":"bluetti-handsfree-1","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":168,"cold_f":20,"reason":""},{"station_id":"bluetti-handsfree-1","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-handsfree-1","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-handsfree-1","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-handsfree-1","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":165,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":165,"cold_f":20,"reason":"The panels can push 9.9A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-handsfree-1","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":157,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":157,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-handsfree-1","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":160,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-handsfree-1","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-handsfree-1","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":155,"cold_f":20,"reason":""},{"station_id":"bluetti-handsfree-1","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":165,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":165,"cold_f":20,"reason":"The panels can push 10A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-handsfree-1","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-handsfree-1","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":153,"cold_f":20,"reason":""},{"station_id":"bluetti-handsfree-1","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":161,"cold_f":20,"reason":""},{"station_id":"bluetti-handsfree-1","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":151,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":151,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-handsfree-1","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-handsfree-1","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":140,"cold_f":20,"reason":""},{"station_id":"bluetti-handsfree-1","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ps72","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ps72","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ps72","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-ps72","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ps72","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ps72","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":198,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ps72","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ps72","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-ps72","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The manual or page does not give a current limit for this input, so current was not checked."},{"station_id":"bluetti-ps72","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"bluetti-pioneer-na","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":180,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":360,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-pioneer-na","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":410,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":368,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-pioneer-na","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":276,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":276,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-pioneer-na","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-pioneer-na","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":480,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-pioneer-na","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":192,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":384,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-pioneer-na","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":195,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":390,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-pioneer-na","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"The panels can push 10A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-pioneer-na","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":368,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"bluetti-pioneer-na","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":363,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-pioneer-na","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":342,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":552,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-premium-100-v2","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":800,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-premium-100-v2","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-100-v2","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on PV input","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":552,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-premium-200-v2","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":800,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"bluetti-premium-200-v2","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on PV input","two_panels_w":500,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"bluetti-premium-200-v2","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on PV input","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"anker-solix-c200-dc","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c200-dc","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c200-dc","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"anker-solix-c200-dc","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c200-dc","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c200-dc","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c200-dc","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c200-dc","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c200-dc","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200-dc","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c200x","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c200x","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c200x","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"anker-solix-c200x","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c200x","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c200x","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c200x","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c200x","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c200x","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c200x","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"anker-solix-c300","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300-dc","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300-dc","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300-dc","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"anker-solix-c300-dc","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300-dc","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300-dc","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300-dc","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300-dc","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300-dc","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300-dc","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300x","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300x","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300x","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"anker-solix-c300x","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300x","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300x","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300x","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300x","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c300x","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c300x","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":148,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":164,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The panels can push 10A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":595,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":151,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":438,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":167,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":396,"cold_f":20,"reason":"The panels can push 9.7A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":226,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":226,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":153,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":320,"cold_f":20,"reason":"The panels can push 8.6A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":600,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":165,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The panels can push 9.9A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":157,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":500,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":165,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The panels can push 10A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":151,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts."},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x-gen-2","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"anker-solix-c1000x","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":180,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":513,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":438,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":396,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":276,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":276,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"anker-solix-c1000x","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":320,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":350,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":239,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":600,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"anker-solix-c1000x","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":192,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":195,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":488,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c1000x","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":697,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":438,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":396,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":469,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":320,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":350,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":239,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":800,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":500,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-c2000-gen-2","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":225,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":250,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-f1500","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":230,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":255,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-f1500","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-f1500","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":233,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":279,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"jackery-solarsaga-100-air","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (29.7V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 32.5V, above the 30V limit. Cold makes panels push more voltage."},{"station_id":"anker-solix-f1500","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":239,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-f1500","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-f1500","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":252,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":240,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":244,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":244,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":251,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":230,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-f1500","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f1500","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on XT60","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"anker-solix-f2600","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":800,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":438,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":396,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":552,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"anker-solix-f2600","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":320,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":350,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":239,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":800,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"anker-solix-f2600","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":500,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f2600","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":800,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":438,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":396,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":700,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"anker-solix-ps200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High-PV","two_panels_w":399,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":320,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":350,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":240,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"anker-solix-ps400","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High-PV","two_panels_w":800,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":500,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3000","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on High-PV + 1 panel on Low-PV","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":800,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":438,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":396,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":700,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"anker-solix-ps200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":320,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":350,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":240,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"anker-solix-ps400","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":800,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":500,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-f3800-plus","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on Solar input + 1 panel on Solar input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":396,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":345,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":345,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"anker-solix-s2000","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":320,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":350,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":239,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":400,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"anker-solix-s2000","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":244,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"anker-solix-s2000","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on XT60i","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":90,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":90,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 27.2V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-100-plus","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":92,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":92,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 27.2V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-100-plus","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 27.2V limit. Cold makes panels push more voltage."},{"station_id":"jackery-explorer-100-plus","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 27.2V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-100-plus","panel_id":"ecoflow-100w-rigid","one_panel":"Works, with a catch","one_panel_w":86,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":86,"cold_f":20,"reason":"Working voltage 17.1V is below the 18V minimum, so charging may drop out in weak light."},{"station_id":"jackery-explorer-100-plus","panel_id":"ecoflow-100w-flexible","one_panel":"Works, with a catch","one_panel_w":86,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":86,"cold_f":20,"reason":"Working voltage 17.1V is below the 18V minimum, so charging may drop out in weak light."},{"station_id":"jackery-explorer-100-plus","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":92,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":92,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":93,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":93,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"ecoflow-175w-rigid","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (25.5V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 27.9V, above the 27.2V limit. Cold makes panels push more voltage."},{"station_id":"jackery-explorer-100-plus","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 27.2V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-100-plus","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":94,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":94,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":98,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":98,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 27.2V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-100-plus","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 27.2V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-100-plus","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":96,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":96,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":98,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":98,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":93,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":95,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":95,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"richsolar-mega-50","one_panel":"Works, with a catch","one_panel_w":50,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":88,"cold_f":20,"reason":"Working voltage 17.6V is below the 18V minimum, so charging may drop out in weak light."},{"station_id":"jackery-explorer-100-plus","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":93,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":93,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":98,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":98,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":92,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":92,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-100-plus","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 27.2V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-100-plus","panel_id":"richsolar-mega-100-flex","one_panel":"Works, with a catch","one_panel_w":86,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":86,"cold_f":20,"reason":"Working voltage 17.1V is below the 18V minimum, so charging may drop out in weak light."},{"station_id":"jackery-explorer-100-plus","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 27.2V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-240-v2","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":90,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":90,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 27V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-240-v2","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":92,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":92,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 27V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-240-v2","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 27V limit. Cold makes panels push more voltage."},{"station_id":"jackery-explorer-240-v2","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 27V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-240-v2","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":86,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":86,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":86,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":86,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":92,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":92,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":93,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":93,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"ecoflow-175w-rigid","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (25.5V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 27.9V, above the 27V limit. Cold makes panels push more voltage."},{"station_id":"jackery-explorer-240-v2","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 27V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-240-v2","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":94,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":94,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":98,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":98,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 27V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-240-v2","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 27V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-240-v2","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":96,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":96,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":98,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":98,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":93,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":95,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":95,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":88,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":93,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":93,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":98,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":98,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":92,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":92,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 27V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-240-v2","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":86,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":86,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-240-v2","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on USB-C (with DC8020-to-USB-C adapter)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 27V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300-v2","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300-v2","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 10A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300-v2","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300-v2","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300-v2","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 9.7A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300-v2","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300-v2","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"jackery-explorer-300-v2","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300-v2","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300-v2","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300-v2","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300-v2","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 8.6A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300-v2","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 7.9A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300-v2","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300-v2","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300-v2","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 6.1A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300-v2","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300-v2","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300-v2","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300-v2","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300-v2","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 9.9A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300-v2","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300-v2","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300-v2","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300-v2","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300-v2","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 10A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300-v2","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300-v2","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300-v2","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300-v2","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300-v2","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300-v2","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300-v2","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300d","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300d","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 10A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300d","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300d","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300d","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 9.7A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300d","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300d","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"jackery-explorer-300d","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300d","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300d","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300d","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300d","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 8.6A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300d","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 7.9A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300d","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300d","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300d","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 6.1A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300d","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300d","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300d","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300d","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300d","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 9.9A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300d","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300d","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300d","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300d","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300d","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 10A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300d","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300d","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300d","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300d","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 6A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-300d","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-300d","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-300d","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-600-v2","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":189,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":193,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"jackery-explorer-600-v2","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC8020","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"jackery-explorer-600-v2","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":193,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-600-v2","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":135,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":135,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":150,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":150,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-1000","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":138,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":138,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":153,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":153,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-1000","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":162,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-1000","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":128,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":128,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":138,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":140,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":140,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":167,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":167,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"jackery-solarsaga-100-air","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":191,"cold_f":20,"reason":"Fine in mild weather (29.7V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 32.5V, above the 30V limit. Cold makes panels push more voltage."},{"station_id":"jackery-explorer-1000","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":140,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":147,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":154,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-1000","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-1000","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":151,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":151,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":144,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":144,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":146,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":146,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":142,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":151,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":151,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":140,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":147,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":138,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":138,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-1000","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":128,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-1000","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on DC input","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"jackery-explorer-1000-plus","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":396,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 11A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-1000-plus","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":202,"two_panels":"Works","two_panels_wiring":"2 panels in series on DC8020","two_panels_w":405,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 11A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-1000-plus","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":304,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":608,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 11A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-1000-plus","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"On a 20°F (-7°C) morning the open-circuit voltage can reach about 63.1V, above 60V."},{"station_id":"jackery-explorer-1000-plus","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":240,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"bluetti-sp200l","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed."},{"station_id":"jackery-explorer-1000-plus","panel_id":"bluetti-pv100fx","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed."},{"station_id":"jackery-explorer-1000-plus","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":800,"cold_f":20,"reason":"On a 20°F (-7°C) morning the open-circuit voltage can reach about 63.1V, above 60V."},{"station_id":"jackery-explorer-1000-plus","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":215,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":430,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 11A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-1000-plus","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1000-plus","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":331,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 12A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-1500-v2","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"jackery-explorer-1500-v2","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":240,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"jackery-explorer-1500-v2","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":234,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 12A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-1500-v2","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-v2","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":331,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":662,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 12A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-1500-ultra","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"jackery-explorer-1500-ultra","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":240,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":800,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"jackery-explorer-1500-ultra","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":234,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":468,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 12A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-1500-ultra","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-1500-ultra","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-2000-v2","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":396,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":331,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"jackery-explorer-2000-v2","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":320,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":350,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":240,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"jackery-explorer-2000-v2","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":234,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-2000-v2","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-explorer-5000-plus","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":189,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":378,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 10.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-5000-plus","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Low-PV (DC8020)","two_panels_w":431,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":193,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":386,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 10.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-5000-plus","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":290,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Low-PV (DC8020)","two_panels_w":290,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 10.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-5000-plus","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Low-PV (DC8020)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Low-PV (DC8020)","two_panels_w":399,"cold_f":20,"reason":"On a 20°F (-7°C) morning the open-circuit voltage can reach about 63.1V, above 60V."},{"station_id":"jackery-explorer-5000-plus","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Low-PV (DC8020)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":239,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Low-PV (DC8020)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"bluetti-sp200l","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Low-PV (DC8020)","two_panels_w":400,"cold_f":20,"reason":"The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed."},{"station_id":"jackery-explorer-5000-plus","panel_id":"bluetti-pv100fx","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Low-PV (DC8020)","two_panels_w":200,"cold_f":20,"reason":"The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed."},{"station_id":"jackery-explorer-5000-plus","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on Low-PV (DC8020)","two_panels_w":504,"cold_f":20,"reason":"On a 20°F (-7°C) morning the open-circuit voltage can reach about 63.1V, above 60V."},{"station_id":"jackery-explorer-5000-plus","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":205,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":410,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 10.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-5000-plus","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Low-PV (DC8020)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Low-PV (DC8020)","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Low-PV (DC8020)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":193,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":386,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 10.5A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-explorer-5000-plus","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Low-PV (DC8020)","two_panels_w":381,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in series on Low-PV (DC8020)","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-explorer-5000-plus","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on Low-PV (DC8020)","two_panels_w":359,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-1000-v2","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":396,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":331,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"jackery-homepower-1000-v2","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":320,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":350,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":240,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"jackery-homepower-1000-v2","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":234,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-v2","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":396,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":331,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":320,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":350,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":240,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":234,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-1000-plus-v2","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":800,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":438,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":396,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":331,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":662,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":320,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":350,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":240,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":800,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":234,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":468,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-2000-plus-v2","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"jackery-homepower-3000","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":331,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":662,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 12A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-homepower-3000","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"On a 20°F (-7°C) morning the open-circuit voltage can reach about 63.1V, above 60V."},{"station_id":"jackery-homepower-3000","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":240,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"bluetti-sp200l","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed."},{"station_id":"jackery-homepower-3000","panel_id":"bluetti-pv100fx","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed."},{"station_id":"jackery-homepower-3000","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":800,"cold_f":20,"reason":"On a 20°F (-7°C) morning the open-circuit voltage can reach about 63.1V, above 60V."},{"station_id":"jackery-homepower-3000","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":234,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":468,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 12A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-homepower-3000","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3000","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":331,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":662,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 12A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-homepower-3600-plus","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"jackery-homepower-3600-plus","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":240,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":800,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"jackery-homepower-3600-plus","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":234,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":468,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 12A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-homepower-3600-plus","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-plus","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":800,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":438,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":331,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":662,"cold_f":20,"reason":"The panels can push 12.7A but this input takes 12A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"On a 20°F (-7°C) morning the open-circuit voltage can reach about 63.1V, above 60V."},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":240,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"bluetti-sp200l","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":"The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed."},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"bluetti-pv100fx","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":"The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed."},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":800,"cold_f":20,"reason":"On a 20°F (-7°C) morning the open-circuit voltage can reach about 63.1V, above 60V."},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":234,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":468,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 12A, so the station caps it. Safe, you just lose some watts."},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"jackery-homepower-3600-pro-max","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on DC8020 + 1 panel on DC8020","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"goalzero-yeti-300","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":180,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":180,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-300","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":184,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-300","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-300","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-300","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":171,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":171,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":184,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":186,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-300","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":187,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":196,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-300","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-300","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":192,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":192,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":195,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":195,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":189,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":186,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":196,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":184,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-300","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":171,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-300","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":180,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":180,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":184,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-500","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":171,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":171,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":184,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":186,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":187,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":196,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":192,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":192,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":195,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":195,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":189,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":186,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":196,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":184,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":171,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-700","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":180,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":180,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-700","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":184,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-700","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-700","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-700","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":171,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":171,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":184,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":186,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-700","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":187,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":196,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-700","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-700","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":192,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":192,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":195,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":195,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":189,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":186,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":196,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":184,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-700","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":171,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-700","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-1500","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on HPP","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":600,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in series on HPP","two_panels_w":438,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":396,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":552,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"anker-solix-ps200","one_panel":"Works, with a catch","one_panel_w":200,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":399,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-1500","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":320,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":350,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":240,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"anker-solix-ps400","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":600,"cold_f":20,"reason":"Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-1500","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on HPP","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in series on HPP","two_panels_w":500,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in series on HPP","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"ecoflow-400w-portable","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":800,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":438,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":396,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":700,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"anker-solix-ps200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":399,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":320,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":350,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":240,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"anker-solix-ps400","one_panel":"Works","one_panel_w":400,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":800,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":500,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on HPP + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-pro-4000","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on HPP","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"ecoflow-400w-portable","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":600,"cold_f":20,"reason":"Fine in mild weather (48V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 52.6V, above the 50V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-1000x","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":438,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":396,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":600,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 50V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-1000x","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":320,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":350,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":240,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 50V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-1000x","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":500,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1000x","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"ecoflow-400w-portable","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":600,"cold_f":20,"reason":"Fine in mild weather (48V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 52.6V, above the 50V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-1500x","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":438,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":396,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":600,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 50V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-1500x","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":320,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":350,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":240,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 50V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-1500x","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":500,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-1500x","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"ecoflow-400w-portable","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":600,"cold_f":20,"reason":"Fine in mild weather (48V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 52.6V, above the 50V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-3000x","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":438,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":396,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":600,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 50V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-3000x","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":320,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":350,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":240,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 50V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-3000x","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":500,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-3000x","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"ecoflow-400w-portable","one_panel":"Works, with a catch","one_panel_w":400,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":600,"cold_f":20,"reason":"Fine in mild weather (48V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 52.6V, above the 50V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-6000x","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":438,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":396,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"bluetti-pv350d","one_panel":"Works","one_panel_w":350,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":600,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 50V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-6000x","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":320,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":350,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"jackery-solarsaga-100-air","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":240,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"bluetti-pv100fx","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 50V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-6000x","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":500,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"richsolar-mega-200-pro","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on High Power Port + 1 panel on 8mm","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-6000x","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on High Power Port","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"goalzero-yeti-500x","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works, with a catch","one_panel_w":150,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":150,"cold_f":20,"reason":"Fine in mild weather (22V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 23.9V, above the 22V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-500x","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.8V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works, with a catch","one_panel_w":150,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":150,"cold_f":20,"reason":"Fine in mild weather (21.5V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 23.5V, above the 22V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-500x","panel_id":"bluetti-pv200d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.6V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"anker-solix-ps100","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 25.9V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"ecoflow-100w-rigid","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":150,"cold_f":20,"reason":"Fine in mild weather (20.3V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 22.4V, above the 22V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-500x","panel_id":"ecoflow-100w-flexible","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":150,"cold_f":20,"reason":"Fine in mild weather (20.3V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 22.4V, above the 22V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-500x","panel_id":"ecoflow-110w-portable","one_panel":"Works, with a catch","one_panel_w":110,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":150,"cold_f":20,"reason":"Fine in mild weather (21.8V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 23.9V, above the 22V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-500x","panel_id":"ecoflow-160w-nextgen","one_panel":"Works, with a catch","one_panel_w":150,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":150,"cold_f":20,"reason":"Fine in mild weather (21.3V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 23.3V, above the 22V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-500x","panel_id":"ecoflow-175w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 25.5V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"jackery-solarsaga-100-prime","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.7V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"bluetti-pv120","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.4V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"bluetti-sp100l","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.6V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"bluetti-sp200l","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.6V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"renogy-eflex-200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 23.4V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"renogy-ntype-200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 23V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"renogy-bifacial-250","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.4V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"renogy-50w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.3V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"renogy-100w-flexible","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.5V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"renogy-200w-flexible","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 23.9V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"richsolar-mega-50","one_panel":"Works, with a catch","one_panel_w":50,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (20.8V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 22.8V, above the 22V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-500x","panel_id":"richsolar-mega-100","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.8V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"richsolar-mega-100-slim","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 23.6V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"richsolar-mega-200","one_panel":"Works, with a catch","one_panel_w":150,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":150,"cold_f":20,"reason":"Fine in mild weather (21.8V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 23.9V, above the 22V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-500x","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-500x","panel_id":"richsolar-mega-100-flex","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":150,"cold_f":20,"reason":"Fine in mild weather (20.4V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 22.3V, above the 22V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-500x","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (22V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 23.9V, above the 22V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-200x","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.8V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (21.5V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 23.5V, above the 22V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-200x","panel_id":"bluetti-pv200d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.6V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"anker-solix-ps100","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 25.9V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"ecoflow-100w-rigid","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (20.3V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 22.4V, above the 22V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-200x","panel_id":"ecoflow-100w-flexible","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (20.3V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 22.4V, above the 22V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-200x","panel_id":"ecoflow-110w-portable","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (21.8V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 23.9V, above the 22V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-200x","panel_id":"ecoflow-160w-nextgen","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (21.3V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 23.3V, above the 22V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-200x","panel_id":"ecoflow-175w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 25.5V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"jackery-solarsaga-100-prime","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.7V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"bluetti-pv120","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.4V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"bluetti-sp100l","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.6V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"bluetti-sp200l","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 24.6V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"renogy-eflex-200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 23.4V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"renogy-ntype-200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 23V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"renogy-bifacial-250","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.4V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"renogy-50w-rigid","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.3V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"renogy-100w-flexible","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.5V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"renogy-200w-flexible","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 23.9V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"richsolar-mega-50","one_panel":"Works, with a catch","one_panel_w":50,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (20.8V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 22.8V, above the 22V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-200x","panel_id":"richsolar-mega-100","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 22.8V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"richsolar-mega-100-slim","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 23.6V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"richsolar-mega-200","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (21.8V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 23.9V, above the 22V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-200x","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"goalzero-yeti-200x","panel_id":"richsolar-mega-100-flex","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":100,"cold_f":20,"reason":"Fine in mild weather (20.4V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 22.3V, above the 22V limit. Cold makes panels push more voltage."},{"station_id":"goalzero-yeti-200x","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on 8mm","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 22V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-500","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":180,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":300,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"dji-power-500","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":300,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-500","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":300,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"dji-power-500","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":300,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-500","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-500","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":300,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":300,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"jackery-solarsaga-100-air","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (29.7V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 32.5V, above the 30V limit. Cold makes panels push more voltage."},{"station_id":"dji-power-500","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":240,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":300,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-500","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-500","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":300,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":192,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":300,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"dji-power-500","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":195,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":300,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"dji-power-500","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":300,"cold_f":20,"reason":"The panels can push 10A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"dji-power-500","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":300,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"dji-power-500","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-500","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-500","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-1000","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":180,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":360,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"dji-power-1000","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-1000","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":368,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"dji-power-1000","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-1000","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-1000","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"jackery-solarsaga-100-air","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (29.7V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 32.5V, above the 30V limit. Cold makes panels push more voltage."},{"station_id":"dji-power-1000","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":240,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-1000","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-1000","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":192,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":384,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"dji-power-1000","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":195,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":390,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"dji-power-1000","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":400,"cold_f":20,"reason":"The panels can push 10A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"dji-power-1000","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":368,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"dji-power-1000","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-1000","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-1000","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-2000","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":180,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":360,"cold_f":20,"reason":"The panels can push 11.5A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"dji-power-2000","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-2000","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":368,"cold_f":20,"reason":"The panels can push 11.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"dji-power-2000","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":396,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-2000","panel_id":"anker-solix-ps100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-2000","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":220,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":320,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":350,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"jackery-solarsaga-100-air","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (29.7V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 32.5V, above the 30V limit. Cold makes panels push more voltage."},{"station_id":"dji-power-2000","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":198,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":240,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-2000","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-2000","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":400,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":192,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":384,"cold_f":20,"reason":"The panels can push 10.4A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"dji-power-2000","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":195,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":390,"cold_f":20,"reason":"The panels can push 12.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"dji-power-2000","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":400,"cold_f":20,"reason":"The panels can push 10A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"dji-power-2000","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":100,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":184,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":368,"cold_f":20,"reason":"The panels can push 10.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts."},{"station_id":"dji-power-2000","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-2000","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":200,"cold_f":20,"reason":""},{"station_id":"dji-power-2000","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-1000-mini","panel_id":"jackery-solarsaga-200-js200e","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"jackery-solarsaga-200-js200d","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"ecoflow-400w-portable","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 48V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-1000-mini","panel_id":"ecoflow-220w-bifacial-nextgen","one_panel":"Works","one_panel_w":219,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"bluetti-pv200d","one_panel":"Works","one_panel_w":198,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":396,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"bluetti-pv350d","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-1000-mini","panel_id":"anker-solix-ps100","one_panel":"Works, with a catch","one_panel_w":100,"two_panels":"Works, with a catch","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":200,"cold_f":20,"reason":"Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage."},{"station_id":"dji-power-1000-mini","panel_id":"anker-solix-ps200","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-1000-mini","panel_id":"ecoflow-100w-rigid","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"ecoflow-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"ecoflow-110w-portable","one_panel":"Works","one_panel_w":110,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":220,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"ecoflow-160w-nextgen","one_panel":"Works","one_panel_w":160,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":320,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"ecoflow-175w-rigid","one_panel":"Works","one_panel_w":175,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":350,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"jackery-solarsaga-100-air","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 29.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-1000-mini","panel_id":"jackery-solarsaga-100-prime","one_panel":"Works","one_panel_w":99,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":198,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"bluetti-pv120","one_panel":"Works","one_panel_w":120,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":239,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"bluetti-sp100l","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"bluetti-sp200l","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"bluetti-pv100fx","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 41.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-1000-mini","panel_id":"anker-solix-ps400","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-1000-mini","panel_id":"renogy-eflex-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"renogy-ntype-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"renogy-bifacial-250","one_panel":"Works","one_panel_w":250,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"renogy-50w-rigid","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"renogy-100w-flexible","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"renogy-200w-flexible","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"richsolar-mega-50","one_panel":"Works","one_panel_w":50,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":100,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"richsolar-mega-100","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"richsolar-mega-100-slim","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"richsolar-mega-200","one_panel":"Works","one_panel_w":200,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":400,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"richsolar-mega-200-pro","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it."},{"station_id":"dji-power-1000-mini","panel_id":"richsolar-mega-100-flex","one_panel":"Works","one_panel_w":100,"two_panels":"Works","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":200,"cold_f":20,"reason":"The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number."},{"station_id":"dji-power-1000-mini","panel_id":"richsolar-mega-200-pro-flex","one_panel":"Don't connect","one_panel_w":0,"two_panels":"Don't connect","two_panels_wiring":"2 panels in parallel on SDC (built-in MPPT, DJI MC4 solar cable)","two_panels_w":0,"cold_f":20,"reason":"Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it."}]}